Search icon

JRSC CONSTRUCTION SERVICES INC

Company Details

Entity Name: JRSC CONSTRUCTION SERVICES INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Inactive
Date Filed: 22 Aug 2023 (a year ago)
Date of dissolution: 27 Sep 2024 (5 months ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2024 (5 months ago)
Document Number: P23000061531
Address: 2525 TRUMAN AVE, PENSACOLA, FL 32505
Mail Address: 2525 TRUMAN AVE, PENSACOLA, FL 32505
ZIP code: 32505
County: Escambia
Place of Formation: FLORIDA

Agent

Name Role Address
SOTZ CHEX, JULIO R Agent 2525 TRUMAN AVENUE, PENSACOLA, FL 32505

President

Name Role Address
SOTZ CHEX, JULIO R President 2525 TRUMAN AVENUE, PENSACOLA, FL 32505

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 No data No data

Documents

Name Date
Domestic Profit 2023-08-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347810483 0418600 2024-10-10 1644 SLATE DR. LOT 9C, PENSACOLA, FL, 32505
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-10-10
Emphasis N: FALL, P: FALL
Case Closed 2025-02-03

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-11-19
Abatement Due Date 2024-12-02
Current Penalty 1659.0
Initial Penalty 2765.0
Final Order 2025-01-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by a guardrail system, safety net system, or personal fall arrest system, or an alternative fall protection measure that meets a provision described in paragraph (b) of this section. a) 1644 Slate Dr. Lot 9C Pensacola, FL. On or about October 10, 2024, and at times prior; The employer allowed his employees to perform roofing activities without fall protection being used, exposing his employees to fall hazard of up to 8 feet 7 inches to the ground below.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-11-19
Abatement Due Date 2024-12-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2025-01-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): training program was not provided to each employee who might be exposed to fall hazards, to enable that employee to recognize the hazards of falling and be trained in the procedures to be followed to minimize these hazards. a) 1644 Slate Dr. Lot 9C Pensacola, FL. On or about October 10, 2024, and at times prior; The employer allowed his employees to perform roofing activities without first ensuring his crew was trained on the hazards associated with falls to include but not limited to setting up and inspecting fall protection exposing his employees to a fall hazard of 8 feet 7 inch to the ground below.

Date of last update: 09 Feb 2025

Sources: Florida Department of State