Search icon

NASSAL FABRICATION SERVICES INC. - Florida Company Profile

Company Details

Entity Name: NASSAL FABRICATION SERVICES INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

NASSAL FABRICATION SERVICES INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 25 Apr 2023 (2 years ago)
Document Number: P23000032564
FEI/EIN Number 92-3735902

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 415 West Kaley St, ORLANDO, FL, 32806, US
Mail Address: 2000 S Colorado Blvd, Ste 2-500, Denver, CO, 80222, US
ZIP code: 32806
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CT CORPORATION SYSTEM Agent 1200 SOUTH PINE ISLAND ROAD, PLANTATION, FL, 33324
Brown Deron L Chairman 415 West Kaley St, ORLANDO, FL, 32806
Kehoe Michael J Director 415 West Kaley St, ORLANDO, FL, 32806
Nassal William P Director 415 West Kaley St, ORLANDO, FL, 32806
Denis Jeff Director 415 West Kaley St, ORLANDO, FL, 32806
Fenton Renee Treasurer 415 West Kaley St, ORLANDO, FL, 32806
Fenton Renee L Secretary 415 West Kaley St, ORLANDO, FL, 32806

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-04-19 415 West Kaley St, ORLANDO, FL 32806 -
CHANGE OF MAILING ADDRESS 2024-04-19 415 West Kaley St, ORLANDO, FL 32806 -

Documents

Name Date
ANNUAL REPORT 2024-04-19
Domestic Profit 2023-04-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346804636 0419730 2023-06-29 415 WEST KALEY STREET, ORLANDO, FL, 32806
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2023-08-10
Emphasis N: HEATNEP
Case Closed 2024-01-02

Related Activity

Type Complaint
Activity Nr 2047016
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100022 A01
Issuance Date 2023-11-28
Current Penalty 4218.2
Initial Penalty 6026.0
Final Order 2024-01-02
Nr Instances 3
Nr Exposed 35
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. a.) On or about June 29, 2023, in the Carpenter Shop: Employees were exposed to excessive amounts of dust on the floor, ceilings, walls, and equipment tables. b.) On or about June 29, 2023, in the High Bay Area where Fiberglass is grinded and sanded and bags of Glass Fiber Reinforced Concrete (GFRC) are opened: the floor and work area was not kept clean and orderly, in that there was a significant buildup of GFRC dust, and molds and other materials were being stored haphazardly throughout the area. c.) On or about June 29, 2023, in the Casting Area: The area was not kept clean and orderly due to the fiberglass and styrene mixture overspray, along with fiberglass materials, trash, and hoses being strewn across the floor.
Citation ID 01002A
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2023-11-28
Current Penalty 4218.2
Initial Penalty 6026.0
Final Order 2024-01-02
Nr Instances 7
Nr Exposed 10
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a.) On or about June 29, 2023, in the Casting Department and High Bay, employees were required to wear 8210 N95 respirators and half-face elastomeric respirators to protect them from Glass Fiber Reinforced Concrete (GFRC) and organic vapor exposures while grinding or sanding on GFRC molds, and when spraying and rolling resin coatings, styrene, and other organic vapors mixtures and the employer had not implemented a worksite-specific respiratory protection program.
Citation ID 01002B
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2023-11-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-01-02
Nr Instances 6
Nr Exposed 10
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a.) On or about 6/29/2023, in the Casting Department and High Bay, employees were required to wear 8210 N95 respirators and half-face elastomeric respirators to protect them from Glass Fiber Reinforced Concrete (GFRC) and organic vapor exposures while grinding or sanding on GFRC molds, and when spraying and rolling resin coatings, styrene , and other organic vapors mixtures and the employer had not provided medical evaluations to each employee required to use a respirator.
Citation ID 01002C
Citaton Type Other
Standard Cited 19100134 F02
Issuance Date 2023-11-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-01-02
Nr Instances 4
Nr Exposed 10
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a.) On or about 6/29/2023, in the Casting Department and High Bay, employees were required to wear 8210 N95 respirators and half-face elastomeric respirators to protect them from Glass Fiber Reinforced Concrete (GFRC) and organic vapor exposures while grinding or sanding on GFRC molds, and when spraying and rolling resin coatings, styrene, and other organic vapors mixtures, and the employer had not provided a fit test to each employee.
Citation ID 01002D
Citaton Type Other
Standard Cited 19100134 G01 I A
Issuance Date 2023-11-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-01-02
Nr Instances 2
Nr Exposed 7
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a.) On or about 6/29/2023, in the Casting Department and High Bay, employees were required to wear 8210 N95 respirators and half-face elastomeric respirators to protect them from Glass Fiber Reinforced Concrete (GFRC) and organic vapor exposures while grinding or sanding on GFRC molds, and when spraying and rolling resin coatings, styrene, and other organic vapors mixtures and two employees had facial hair that came between the sealing surface of the facepiece and the face.
Citation ID 01002E
Citaton Type Serious
Standard Cited 19100134 K
Issuance Date 2023-11-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-01-02
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: a.) On or about 06/29/2023, in the Casting Department and High Bay, employees were required to wear 8210 N95 respirators and half-face elastomeric respirators to protect them from Glass Fiber Reinforced Concrete (GFRC) and organic vapor exposures while grinding or sanding on GFRC molds, and when spraying and rolling resin coatings, styrene, and other organic vapors mixtures, and the employer had not provided the employees with respiratory protection training.
Citation ID 01003
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2023-11-28
Current Penalty 4218.2
Initial Penalty 6026.0
Final Order 2024-01-02
Nr Instances 2
Nr Exposed 10
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a.) On or about June 29, 2023, in the Casting Department and High Bay, employees were exposed to hazardous chemicals including, but not limited to, Glass Fiber Reinforced Concrete (GFRC) while grinding or sanding on GFRC molds, and when spraying and rolling resin coatings, styrene, and other organic vapors mixtures, and the employer had not provided effective hazard communication training on the health hazards associated with these chemicals.

Date of last update: 02 Apr 2025

Sources: Florida Department of State