Search icon

ROMERO GROUP CONSTRUCTION INC - Florida Company Profile

Company Details

Entity Name: ROMERO GROUP CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ROMERO GROUP CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 13 Apr 2023 (2 years ago)
Document Number: P23000029474
FEI/EIN Number 92-3550280

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1705 GADSEN BLVD, ORLANDO, FL, 32812
Mail Address: 1705 GADSEN BLVD, ORLANDO, FL, 32812
ZIP code: 32812
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ROMERO JOSE B President 1705 GADSEN BLVD, ORLANDO, FL, 32812
ROMERO JOSE B Agent 1705 GADSEN BLVD, ORLANDO, FL, 32812

Documents

Name Date
ANNUAL REPORT 2024-04-29
Domestic Profit 2023-04-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347066862 0419730 2023-10-24 16235 POINT ROCK DR LOT 306, WINTER GARDEN, FL, 34787
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2023-10-24
Emphasis N: FALL, P: FALL
Case Closed 2024-04-12

Related Activity

Type Inspection
Activity Nr 1706397
Safety Yes
Type Inspection
Activity Nr 1705698
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2023-11-07
Current Penalty 2679.0
Initial Penalty 3572.0
Final Order 2024-01-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying objects while using a nail gun. a) On or about October 24, 2023, employees were working on the roof located on lot 306, were exposed to eye and/or facial hazards, in that eye protection was not worn while conducting decking activities using a pneumatic nail gun.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-11-07
Current Penalty 4687.5
Initial Penalty 6250.0
Final Order 2024-01-09
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a) On or about October 24, 2023, employees were working on the roof located on lot 306, were exposed to 20-feet 8-inches and 19-feet 4-inches fall hazards, in that fall protection was not used while conducting decking activities.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2023-11-07
Abatement Due Date 2023-12-05
Current Penalty 375.75
Initial Penalty 501.0
Final Order 2024-01-09
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about October 24, 2023, at lot # 306, employer did not have fall protection training certificates for employees conducting roofing activities on a roof approximately 20 feet high.