Entity Name: | VBUILD CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
VBUILD CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 01 Mar 2023 (2 years ago) |
Last Event: | AMENDMENT |
Event Date Filed: | 25 May 2023 (2 years ago) |
Document Number: | P23000018323 |
FEI/EIN Number |
32-0720067
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2295 S. HIAWASSEE RD, SUITE 205, ORLANDO, FL, 32835, US |
Mail Address: | 2295 S. HIAWASSEE RD, SUITE 205, ORLANDO, FL, 32835, US |
ZIP code: | 32835 |
County: | Orange |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SANTOS ANGELO VALDIR | President | 5367 CYPRESS CT, ORLANDO, FL, 32811 |
SANTOS ANGELO VALDIR | Agent | 5267 CYPRESS CT, ORLANDO, FL, 32811 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
AMENDMENT | 2023-05-25 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2023-05-25 | 2295 S. HIAWASSEE RD, SUITE 205, ORLANDO, FL 32835 | - |
CHANGE OF MAILING ADDRESS | 2023-05-25 | 2295 S. HIAWASSEE RD, SUITE 205, ORLANDO, FL 32835 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-05-01 |
Amendment | 2023-05-25 |
Domestic Profit | 2023-03-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347275059 | 0419730 | 2024-02-12 | 16116 HALSEY BAY ALY LOT 518, WINTER GARDEN, FL, 34787 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1727602 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-03-25 |
Current Penalty | 4839.0 |
Initial Penalty | 4839.0 |
Final Order | 2024-04-18 |
Nr Instances | 4 |
Nr Exposed | 7 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a. On or about February 12, 2024, on Lot 518, employer did not enforce the use of fall protection while employees were framing in front of the house at a height 19-feet 10-inches, exposing employees to fall hazards. b. On or about February 12, 2024, on Lot 518, employer did not enforce the use of fall protection while employees were framing in front of the house at a height 8-feet 7-inches, exposing employees to fall hazards. c. On or about February 12, 2024, on Lot 518, employees were exposed to fall hazards of approximate 8-feet, in that the use of a guardrail system was not provided on the residential stairs while the employees conducted framing work activities. d. On or about February 12, 2024, on Lot 518, employees were exposed to fall hazards of approximate 11-feet, in that the use of a guardrail system was not provided on the second floor patio door while the employees conducted framing work activities. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 B01 |
Issuance Date | 2024-03-25 |
Abatement Due Date | 2024-04-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-04-18 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. On or about February 12, 2024, the employer did not have fall protection training certificates for employees conducting framing activities at the site. |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2023-10-06 |
Emphasis | N: FALL, P: FALL |
Related Activity
Type | Referral |
Activity Nr | 2097212 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1706477 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2023-11-28 |
Current Penalty | 2846.0 |
Initial Penalty | 2846.0 |
Final Order | 2024-01-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step. a. On or about October 6th, 2023, at the site, work was being performed while standing on the top step of a Little giant A-frame ladder approximately at a height of 6 feet, exposing employees to fall hazards. |
Date of last update: 01 Mar 2025