Search icon

KAOLA CONSTRUCTION INC - Florida Company Profile

Company Details

Entity Name: KAOLA CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

KAOLA CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 20 Dec 2022 (2 years ago)
Date of dissolution: 27 Sep 2024 (7 months ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2024 (7 months ago)
Document Number: P22000093446
Address: 1508 CANDLEWYCK DR, ORLANDO, FL, 32807, US
Mail Address: 1508 CANDLEWYCK DR, ORLANDO, FL, 32807, US
ZIP code: 32807
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ESTRADA ROMERO CARLOS D President 1508 CANDLEWYCK DR, ORLANDO, FL, 32807
ESTRADA ROMERO CARLOS D Agent 1508 CANDLEWYCK DR, ORLANDO, FL, 32807

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -

Documents

Name Date
Domestic Profit 2022-12-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347199101 0419730 2023-11-20 11989 LANGUAGE WAY, ORLANDO, FL, 32832
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2023-11-20
Emphasis N: FALL
Case Closed 2024-04-18

Related Activity

Type Complaint
Activity Nr 2103550
Safety Yes
Health Yes
Type Inspection
Activity Nr 1711786
Safety Yes
Type Inspection
Activity Nr 1712182
Safety Yes
Type Inspection
Activity Nr 1712132
Safety Yes
Type Inspection
Activity Nr 1712443
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2024-03-07
Abatement Due Date 2024-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a. On or about November 20, 2023, at the left side and the front of the building, employees were exposed to a 13 feet 3 inch fall hazard while performing stucco activities, in that the scaffold was not fully planked and parts of the platform was missing or damaged.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2024-03-07
Abatement Due Date 2024-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. The scaffold structure was used as a means of access. a) On or about November 20, 2023; at the front and the left side of the building, employees were exposed to a 13 feet 3 inch fall hazard, in that, employees were working on 1st and 2nd tier of the scaffold installing stucco and were not provided a safe means of access to upper and lower levels of the scaffold.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2024-03-07
Abatement Due Date 2024-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a.) On or about November 20, 2023: at the front and left side of the building, an employee was exposed to a 13 feet 3-inch fall hazard, in that, the scaffold was not dismantled under the supervision of a competent person.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2024-03-07
Abatement Due Date 2024-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about November 20, 2023; at the left side of the building, employees performing stucco work on the scaffold were exposed to 13 feet 3 inch fall hazards, in that guardrails were not provided.

Date of last update: 02 Apr 2025