Entity Name: | THE BROTHERS PLATINUM ROOF INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
THE BROTHERS PLATINUM ROOF INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 07 Dec 2022 (2 years ago) |
Document Number: | P22000090594 |
FEI/EIN Number |
92-1316942
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2450 WEEPING FIG AVE, APOPKA, FL, 32703, US |
Mail Address: | 2450 WEEPING FIG AVE, APOPKA, FL, 32703, US |
ZIP code: | 32703 |
County: | Orange |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
CRUZ SOREANO OLBIN G | President | 2450 WEEPING FIG AVE, APOPKA, FL, 32703 |
CRUZ SOREANO HERLIN | Vice President | 2450 WEEPING FIG AVE, APOPKA, FL, 32703 |
CRUZ SOREANO HERLIN | Agent | 2450 WEEPING FIG AVE, APOPKA, FL, 32703 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2024-01-16 | 2450 WEEPING FIG AVE, APT 302, APOPKA, FL 32703 | - |
CHANGE OF MAILING ADDRESS | 2024-01-16 | 2450 WEEPING FIG AVE, APT 302, APOPKA, FL 32703 | - |
REGISTERED AGENT ADDRESS CHANGED | 2024-01-16 | 2450 WEEPING FIG AVE, APT 302, APOPKA, FL 32703 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-01-16 |
ANNUAL REPORT | 2023-01-11 |
Domestic Profit | 2022-12-07 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347354268 | 0419700 | 2024-03-18 | 1 WHITE HURST LANE, PALM COAST, FL, 32164 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1735298 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2024-04-03 |
Current Penalty | 2212.2 |
Initial Penalty | 3687.0 |
Final Order | 2024-04-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. At a temporally jobsite located at 1 White Hurst Lane, in Palm Coast, FL: On or about March 18, 2024, the employer exposed employees to head injuries, in that protective helmets (hard hats) were not utilized by employees while picking up debris around the home and passing material to the employees at the roof level. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-04-03 |
Current Penalty | 3871.2 |
Initial Penalty | 6452.0 |
Final Order | 2024-04-15 |
Nr Instances | 1 |
Nr Exposed | 8 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a. At a temporary worksite located at 1 White Hurst Lane, in Palm Coast, FL: On or about March 18, 2024, the employer exposed employees to fall hazards, in that the ladder rails did not extend 3 feet above the upper landing surface of the roof at the eave. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-04-03 |
Current Penalty | 3871.2 |
Initial Penalty | 6452.0 |
Final Order | 2024-04-15 |
Nr Instances | 1 |
Nr Exposed | 8 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On a 5:12 roof pitch, at a temporally jobsite located at 1 White Hurst Lane, in Palm Coast, FL: On or about March 18, 2024, the employer exposed employees to fall hazards, in that the employer did not ensure that fall protection was utilized by the employees while performing roofing work. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State