Search icon

THE BROTHERS PLATINUM ROOF INC

Company Details

Entity Name: THE BROTHERS PLATINUM ROOF INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Active
Date Filed: 07 Dec 2022 (2 years ago)
Document Number: P22000090594
FEI/EIN Number 92-1316942
Address: 2450 WEEPING FIG AVE, APT 302, APOPKA, FL 32703
Mail Address: 2450 WEEPING FIG AVE, APT 302, APOPKA, FL 32703
ZIP code: 32703
County: Orange
Place of Formation: FLORIDA

Agent

Name Role Address
CRUZ SOREANO, HERLIN Agent 2450 WEEPING FIG AVE, APT 302, APOPKA, FL 32703

President

Name Role Address
CRUZ SOREANO, OLBIN G President 2450 WEEPING FIG AVE, APT 302 APOPKA, FL 32703

Vice President

Name Role Address
CRUZ SOREANO, HERLIN Vice President 2450 WEEPING FIG AVE, APT 302 APOPKA, FL 32703

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-01-16 2450 WEEPING FIG AVE, APT 302, APOPKA, FL 32703 No data
CHANGE OF MAILING ADDRESS 2024-01-16 2450 WEEPING FIG AVE, APT 302, APOPKA, FL 32703 No data
REGISTERED AGENT ADDRESS CHANGED 2024-01-16 2450 WEEPING FIG AVE, APT 302, APOPKA, FL 32703 No data

Documents

Name Date
ANNUAL REPORT 2024-01-16
ANNUAL REPORT 2023-01-11
Domestic Profit 2022-12-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347354268 0419700 2024-03-18 1 WHITE HURST LANE, PALM COAST, FL, 32164
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2024-03-18
Emphasis N: FALL
Case Closed 2024-05-07

Related Activity

Type Inspection
Activity Nr 1735298
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2024-04-03
Current Penalty 2212.2
Initial Penalty 3687.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. At a temporally jobsite located at 1 White Hurst Lane, in Palm Coast, FL: On or about March 18, 2024, the employer exposed employees to head injuries, in that protective helmets (hard hats) were not utilized by employees while picking up debris around the home and passing material to the employees at the roof level.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-04-03
Current Penalty 3871.2
Initial Penalty 6452.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a. At a temporary worksite located at 1 White Hurst Lane, in Palm Coast, FL: On or about March 18, 2024, the employer exposed employees to fall hazards, in that the ladder rails did not extend 3 feet above the upper landing surface of the roof at the eave.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-04-03
Current Penalty 3871.2
Initial Penalty 6452.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On a 5:12 roof pitch, at a temporally jobsite located at 1 White Hurst Lane, in Palm Coast, FL: On or about March 18, 2024, the employer exposed employees to fall hazards, in that the employer did not ensure that fall protection was utilized by the employees while performing roofing work.

Date of last update: 11 Feb 2025

Sources: Florida Department of State