Search icon

AJF PLASTERING AND MORE INC - Florida Company Profile

Company Details

Entity Name: AJF PLASTERING AND MORE INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

AJF PLASTERING AND MORE INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 01 Nov 2022 (2 years ago)
Last Event: AMENDMENT
Event Date Filed: 01 Dec 2023 (a year ago)
Document Number: P22000083240
FEI/EIN Number 88-4341330

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 12340 NW 5TH CT, FORT LAUDERDALE, FL, 33325
Mail Address: 12340 NW 5TH CT, FORT LAUDERDALE, FL, 33325
ZIP code: 33325
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ESPINOZA FERNANDEZ FREDDY L Vice President 3150 SW 114TH TERRACE APT 205, MIRAMAR, FL, 33025
REYALVAREZ SEQUEIRA JADER A President 12340 NW 5TH CT, FORT LAUDERDALE, FL, 33325
ESPINOZA KENIA Secretary 12340 NW 5TH CT, FORT LAUDERDALE, FL, 33325
SD TAX LLC Agent -

Events

Event Type Filed Date Value Description
AMENDMENT 2023-12-01 - -
CHANGE OF PRINCIPAL ADDRESS 2023-12-01 12340 NW 5TH CT, FORT LAUDERDALE, FL 33325 -
CHANGE OF MAILING ADDRESS 2023-12-01 12340 NW 5TH CT, FORT LAUDERDALE, FL 33325 -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J25000070750 ACTIVE COSO24065812 COUNTY CT, BROWARD CTY, FL 2025-01-19 2030-01-31 $23228.81 H&E EQUIPMENT SERVICES, INC., 7500 PECUE LANE, BATON ROUGE, LA, 70809

Documents

Name Date
ANNUAL REPORT 2024-04-30
Amendment 2023-12-01
ANNUAL REPORT 2023-04-04
Domestic Profit 2022-11-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347306144 0418800 2024-02-23 20775 NW 17TH AVE LAGUNA GARDENS, MIAMI GARDENS, FL, 33014
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-02-23
Emphasis N: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1730829
Safety Yes
Type Inspection
Activity Nr 1731211
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2024-08-16
Abatement Due Date 2024-09-12
Current Penalty 4840.2
Initial Penalty 8067.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on a scaffold more than 10 feet (3.1 m) above a lower level were not protected from falling to a lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section: On or about February 23, 2024, at 20775 NW 17th Ave, Laguna Gardens, Miami Gardens, FL 33014, an employee was exposed to a 12-foot fall hazard while working from a tubular welded frame scaffold that had cross braces as guardrails but lacked midrails.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2024-08-16
Abatement Due Date 2024-09-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedures to control or minimize those hazards: On or about February 23, 2024, at 20775 NW 17th Ave, Laguna Gardens, Miami Gardens, FL 33014 a. An employee was exposed to a 12-foot fall hazard while working from a tubular welded frame scaffold without training. b. Employees were exposed to a fall hazard of up to 48-foot while working from aerial lifts without training.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-08-16
Abatement Due Date 2024-09-12
Current Penalty 6775.2
Initial Penalty 11292.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about February 23, 2024, at 20775 NW 17th Ave, Laguna Gardens, Miami Gardens, FL 33014, employees were exposed to a fall hazard of up to 36 feet while working from balconies without being protected from falling.
Citation ID 02001A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2024-08-16
Abatement Due Date 2024-09-12
Current Penalty 543.6
Initial Penalty 906.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) On or about February 23, 2024, at 20775 NW 17th Ave, Laguna Gardens, Miami Gardens, FL 33014, the employer did not implement a hazard communication program for protecting employees from a chemical hazard presented by materials (i.e. Titan stucco cement, Lanco concrete bonding agent CB-1001) they worked while performing plastering work.
Citation ID 02001B
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 2024-08-16
Abatement Due Date 2024-09-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical: (Construction reference: 1926.59) On or about February 23, 2024, at 20775 NW 17th Ave, Laguna Gardens, Miami Gardens, FL 33014, the safety data sheets for Titan stucco cement and Lanco concrete bonding agent CB-1001 were not maintained, exposing employees to a chemical hazard.
Citation ID 02001C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2024-08-16
Abatement Due Date 2024-09-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) On or about February 23, 2024, at 20775 NW 17th Ave, Laguna Gardens, Miami Gardens, FL 33014, the employer did not provide training to employees who worked with hazardous materials (i.e. Titan stucco cement and Lanco concrete bonding agent CB-1001) as evidenced by, among other conditions; employees lacked knowledge of hazards presented by materials; employees lacked knowledge of use, location and availability of safety data sheets, employees lacked knowledge of company's hazard communication program details and availability, etc.

Date of last update: 01 Mar 2025

Sources: Florida Department of State