Search icon

LONGHORN ROOFING INC - Florida Company Profile

Company Details

Entity Name: LONGHORN ROOFING INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

LONGHORN ROOFING INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 19 Oct 2022 (3 years ago)
Date of dissolution: 05 Jan 2025 (3 months ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 05 Jan 2025 (3 months ago)
Document Number: P22000080263
FEI/EIN Number 884198971

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1065 S JOHN RODES BLVD, Melbourne, FL, 32904, US
Mail Address: 1065 S John Rhodes Blvd, Melbourne, FL, 32904, US
ZIP code: 32904
County: Brevard
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MENDEZ SONIA President 1065 S JOHN RODES BLVD, Melbourne, FL, 32904
MENDEZ SONIA Agent 1065 S JOHN RODES BLVD, Melbourne, FL, 32904

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-01-16 1065 S JOHN RODES BLVD, Melbourne, FL 32904 -
REGISTERED AGENT NAME CHANGED 2024-01-16 MENDEZ, SONIA -
REGISTERED AGENT ADDRESS CHANGED 2024-01-16 1065 S JOHN RODES BLVD, Melbourne, FL 32904 -
CHANGE OF MAILING ADDRESS 2023-08-29 1065 S JOHN RODES BLVD, Melbourne, FL 32904 -

Documents

Name Date
VOLUNTARY DISSOLUTION 2025-01-05
ANNUAL REPORT 2024-01-16
Reg. Agent Change 2023-10-02
ANNUAL REPORT 2023-01-17
Domestic Profit 2022-10-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347927527 0418800 2024-12-11 2151 BRISBANE STREET, PORT SAINT LUCIE, FL, 34984
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-12-11
Emphasis N: FALL, P: FALL
346819568 0419700 2023-07-10 372 61ST STREET, JACKSONVILLE, FL, 32209
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2023-07-11
Emphasis L: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1681953
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2023-09-13
Current Penalty 0.0
Initial Penalty 6026.0
Final Order 2023-10-10
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee was using eye or face protection when exposed to eye or face hazards from flying particles. a. On the roof of a temporary residential worksite, located at 372 West 61st Street, Jacksonville, FL 32208: On or about July 10, 2023, the employer exposed employees to eye injury hazards caused by airborne debris and flying objects, in that eye protection was not utilized by employees, while using a blower to blow off the debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2023-09-13
Current Penalty 10044.5
Initial Penalty 14063.0
Final Order 2023-10-10
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a. On a 2:12 pitched roof of a residential worksite, located at 372 61st Street, Jacksonville, FL 32208: On or about July 10, 2023, the employer exposed 4 employees to fall hazards, in that, fall protection was not utilized by the employee while tearing off an old roof system.
Citation ID 02001
Citaton Type Other
Standard Cited 19261053 B01
Issuance Date 2023-09-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-10-10
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: a. At a temporary residential work site, located at 372 61st Street, Jacksonville, FL 32208, : On or about July 10, 2023, the employer exposed four employee to fall hazards, in that the ladder's side rails were not extended 3 feet above the land and tied off. The employees were being exposed to fall hazards up to 10 feet.