Search icon

TOMAS CARPENTRY INC - Florida Company Profile

Company Details

Entity Name: TOMAS CARPENTRY INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

TOMAS CARPENTRY INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 16 Aug 2022 (3 years ago)
Document Number: P22000064561
FEI/EIN Number 88-3791875

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1001 36TH ST APT 178, WEST PALM BEACH, FL, 33407, US
Mail Address: 1001 36TH ST APT 178, WEST PALM BEACH, FL, 33407, US
ZIP code: 33407
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MORALES TOMAS ALVARO F President 1001 36TH ST APT 178, WEST PALM BEACH, FL, 33407
MORALES TOMAS ALVARO F Agent 1001 36TH ST APT 178, WEST PALM BEACH, FL, 33407

Documents

Name Date
ANNUAL REPORT 2025-01-20
ANNUAL REPORT 2024-01-10
ANNUAL REPORT 2023-01-28
Domestic Profit 2022-08-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347616492 0418800 2024-07-15 LOT 339 2650-C 27.212644,-80306384, PORT SAINT LUCIE, FL, 34984
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-07-15
Emphasis N: FALL

Related Activity

Type Referral
Activity Nr 2183171
Safety Yes
347370470 0419730 2024-03-26 2276 CERULEAN DR NW TIMBERS AT EVERLAND 2243 ANTARUS DRIVE NW, PALM BAY, FL, 32907
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-03-26
Emphasis N: FALL
Case Closed 2024-09-01

Related Activity

Type Referral
Activity Nr 2144559
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260502 D16 III
Issuance Date 2024-04-16
Current Penalty 2903.4
Initial Penalty 4839.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) On or about March 26, 2024, at the jobsite: the employer did not ensure the proper use of fall protection, in that the employer allowed the employee to use a 6 foot Max Force Energy Absorber model 3004, a 4 foot Palmer Safety Anchor Web Strap Part A4125000, a Max Force 50 foot 5/8 inch lifeline model 3200, an Anchor Safety Full Body Harness model 6069g, while employees installed footings and facia on an approximately 14 foot roof, with a pitch of 5/12 allowing the employee to free fall more than 6 feet.
Citation ID 02001
Citaton Type Other
Standard Cited 19040039 A02
Issuance Date 2024-04-16
Current Penalty 2074.2
Initial Penalty 3457.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.39(a)(2):The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization. a) On or about March 23, 2024, the employer failed to report to OSHA within 24-hours a work-related in-patient hospitalization of an employee. The employer notified OSHA on March 25, 2024, of the in-patient hospitalization.
Citation ID 02002
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2024-04-16
Abatement Due Date 2024-06-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1):The employer did not verify fall protection training by preparing a written certification record. a) On or about March 26, 2024, at the jobsite, the employer did not verify fall protection training by preparing a written certification record for employees exposed to 14 foot falls while installing footings and facia on a 5/12 pitched roof.

Date of last update: 01 Mar 2025