Search icon

BIG HAMMER LLC - Florida Company Profile

Company Details

Entity Name: BIG HAMMER LLC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

BIG HAMMER LLC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 02 Aug 2022 (3 years ago)
Date of dissolution: 22 Sep 2023 (a year ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2023 (a year ago)
Document Number: P22000061277
Address: 250 HIAWATHA FARMS RD, MONTICELLO, FL, 32344, US
Mail Address: 250 HIAWATHA FARMS RD, MONTICELLO, FL, 32344, US
ZIP code: 32344
County: Jefferson
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
TUCKER TIMOTHY L President 250 HIAWATHA FARMS RD, MONTICELLO, FL, 32344
TUCKER TIMOTHY L Agent 250 HIAWATHA FARMS RD, MONTICELLO, FL, 32344

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2023-09-22 - -

Documents

Name Date
Domestic Profit 2022-08-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346158009 0419700 2022-08-18 3025 SCHOOL HOUSE RD., TALLAHASSEE, FL, 32311
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2022-08-24
Emphasis L: FALL
Case Closed 2024-10-16

Related Activity

Type Accident
Activity Nr 1935467
Type Referral
Activity Nr 1935156
Safety Yes
Type Inspection
Activity Nr 1629332
Safety Yes
Type Inspection
Activity Nr 1616161
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2023-01-30
Abatement Due Date 2023-02-24
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-02-24
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall, struck-by and crushed-by hazards associated with the inadequate storage and installation of prefabricated roof trusses: a. On or about August 17, 2022, at the Amenity building construction site in Tallahassee, Florida: The employer exposed employees to stuck-by and crush-by hazard, in that roof trusses were not stored, handled and installed in accordance with the manufacturer's instructions to prevent lateral bending and structural damage.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2023-01-30
Current Penalty 15625.0
Initial Penalty 15625.0
Final Order 2023-02-24
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about August 17, 2022, at the Amenity building construction site in Tallahassee, Florida: during roof truss erection, the crew standing on the top wall or on roof truss components such as, but not limited to web members and bottom chord of the trusses, were not protected from a 12-foot fall hazard by the use of a fall protection system.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261428 A
Issuance Date 2023-01-30
Abatement Due Date 2023-02-24
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-02-24
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1428(a): The employer of the signal person did not ensure that each signal person met the Qualifications Requirements (paragraph (c) of this section) prior to giving any signals: a. On or about August 17, 2022, at the Amenity building construction site in Tallahassee, Florida: during the lifting and hoisting of 45-foot-long span roof trusses, the employer exposed employees to a struck-by hazard, in that; an employee performing hand signal activities was not qualified for the task.