342226453
|
0418800
|
2017-04-05
|
2901 INDUSTRIAL AVENUE 3, FORT PIERCE, FL, 34946
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-04-05
|
Case Closed |
2018-08-29
|
Related Activity
Type |
Complaint |
Activity Nr |
1197373 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1222726 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100132 D01 I |
Issuance Date |
2017-10-03 |
Abatement Due Date |
2017-10-30 |
Current Penalty |
1901.0 |
Initial Penalty |
3802.0 |
Final Order |
2017-10-30 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: On or about April 5th, 2017, at the Lamination area of the at the jobsite located at 2901 Industrial Ave 3, Fort Pierce, FL 34946, the employer did not select and have each affected employee use chemical resistant gloves and long resistant pants or any protective device as part of the PPE when using his bare hands to clean tools with acetone (skin irritation) and apply resin (styrene, skin corrosion) and Cadox M-30A (MEKP, skin burns). |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2017-10-03 |
Abatement Due Date |
2017-11-30 |
Current Penalty |
1901.0 |
Initial Penalty |
3802.0 |
Final Order |
2017-10-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about April 5th, 2017, at the Lamination area of the at the jobsite located at 2901 Industrial Ave 3, Fort Pierce, FL 34946, the employer did not establish and implement a written respiratory protection program for employees who were required to wear respiratory protection such as: 1. NIOSH approved brand SAS Safety, full face elastomeric respirator, model Opti-Fit with combined filters for acid and organic and N95 particulate pre-filter. 2. NIOSH approved brand SAS Safety, half face elastomeric respirator, model Multi-use with combined filters for acid and organic and N95 particulate pre-filter. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2017-10-03 |
Abatement Due Date |
2017-11-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-30 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about April 5th, 2017, at the Lamination area of the at the jobsite located at 2901 Industrial Ave 3, Fort Pierce, FL 34946, the employer did not provide a medical evaluation to determine the employee's ability to use respirators NIOSH approved brands such as SAS Safety, full face elastomeric respirator, model Opti-Fit with combined filters for acid and organic and N95 particulate pre-filter; and half face elastomeric respirator, model Multi-use with combined filters for acid and organic and N95 particulate pre-filters. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100134 F02 |
Issuance Date |
2017-10-03 |
Abatement Due Date |
2017-11-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-30 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: On or about April 5th, 2017, at the Lamination area of the at the jobsite located at 2901 Industrial Ave 3, Fort Pierce, FL 34946, the employer did not provide annual fit test to employees using a tight-fitting SAS Safety, full and half face elastomeric respirator. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100134 K01 I |
Issuance Date |
2017-10-03 |
Abatement Due Date |
2017-10-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-30 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(1)(i): The employer did not ensure that each employee could demonstrate knowledge of why the respirator was necessary and how improper fit, usage, or maintenance could compromise the protective effect of the respirator: On or about April 5th, 2017, at the Lamination area of the at the jobsite located at 2901 Industrial Ave 3, Fort Pierce, FL 34946, the employer did not ensure that each employee could demonstrate knowledge of why the respirator was necessary and how improper fit, usage, or maintenance could compromise the protective effect of the respirator to employees using a tight-fitting SAS Safety, full and half face elastomeric respirators. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2017-10-03 |
Abatement Due Date |
2017-10-30 |
Current Penalty |
1901.0 |
Initial Penalty |
3802.0 |
Final Order |
2017-10-30 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about April 5th, 2017, at the Lamination area of the at the jobsite located at 2901 Industrial Ave 3, Fort Pierce, FL 34946, the employer did not implement elements of the written hazard communication program that they developed for a worksite where employees were exposed to chemicals such as, but not limited to acetone, styrene and MEKP, when performing lamination and other related processes. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2017-10-03 |
Abatement Due Date |
2017-10-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-30 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about April 5th, 2017, at the Lamination area of the at the jobsite located at 2901 Industrial Ave 3, Fort Pierce, FL 34946, the employer did not provide training on the hazards; and information in accordance with the Globally Harmonized System of Classification and Labeling of Chemicals, to employees who are exposed to chemicals such as, but not limited to acetone, styrene and MEKP, when performing activities of lamination and other related processes. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100141 A04 II |
Issuance Date |
2017-10-03 |
Abatement Due Date |
2017-10-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-30 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(a)(4)(ii): Wastes were not removed as often as necessary to maintain the place of employment in a sanitary condition: On or about April 5th, 2017, at the Lamination area of the at the jobsite located at 2901 Industrial Ave 3, Fort Pierce, FL 34946, the employer did not maintain the facility in a sanitary condition in that there was an accumulation of fiberglass adhered to tables, materials and walls. |
|
Citation ID |
02002B |
Citaton Type |
Other |
Standard Cited |
19100141 G04 |
Issuance Date |
2017-10-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-30 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(g)(4): Food or beverages were stored in area(s) exposed to toxic material(s): On or about April 5th, 2017, at the Lamination area of the at the jobsite located at 2901 Industrial Ave 3, Fort Pierce, FL 34946, the employer permitted the employees to store and consume food in the lamination area where toxic chemicals such as but no limited to DCPD Laminator, Resin (styrene) and CADOX M-30A (MEKP). |
|
|
342227261
|
0418800
|
2017-04-05
|
2901 INDUSTRIAL AVENUE 3, FORT PIERCE, FL, 34946
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-04-12
|
Case Closed |
2019-02-11
|
Related Activity
Type |
Complaint |
Activity Nr |
1197373 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1222645 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 E01 V |
Issuance Date |
2017-06-16 |
Current Penalty |
2509.8 |
Initial Penalty |
4183.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(e)(1)(v): Unless otherwise specified in this section, mobile ladder stands and platforms with a top step height of 4 feet (1.2 m) or above did not have handrails with a vertical height of 29.5 inches (75 cm) to 37 inches (94 cm), measured from the front edge of a step (NOTE TO PARAGRAPH (e)(1)(v) OF THIS SECTION: Removable gates or non-rigid members, such as chains, may be used instead of handrails in special-use applications.) On or about 4/5/2017, at the lamination department of the above addressed worksite, an employee was exposed to a fall hazard of 4'-4" while accessing a boat hull with a mobile ladder stand that lacked handrails. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100106 E06 II |
Issuance Date |
2017-06-16 |
Abatement Due Date |
2017-06-26 |
Current Penalty |
2509.8 |
Initial Penalty |
4183.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degree F (37.8 degree C), were dispensed into containers without the containers being electrically interconnected: On or about 4/5/2017, at the lamination department of the above addressed worksite, employees were exposed to a fire hazard while residual resin (DCPD Laminating Resin), contained in a 55-gallon drum was transferred to another drum without being electrically interconnected. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2017-06-16 |
Current Penalty |
3346.2 |
Initial Penalty |
5577.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about 4/5/2017, at the above addressed worksite, employees were exposed to struck and caught by hazards while operating a powered industrial truck (i.e. TCM Model FCG25F9, Maximum load 4600 lbs) without being trained and/or evaluated. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2017-06-16 |
Current Penalty |
3346.2 |
Initial Penalty |
5577.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about 4/5/2017, at the finishing department of the above addressed worksite, an employee was exposed to an electrical hazard while using a fan which lacked of a ground prong on its attachment plug. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2017-06-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about 4/5/2017, at the lamination department of the above addressed worksite, an electrical extension cord lacked of strain relief at the female end attachment plug, exposing employees to an electrical hazard. |
|
Citation ID |
01004C |
Citaton Type |
Serious |
Standard Cited |
19100334 A02 I |
Issuance Date |
2017-06-16 |
Abatement Due Date |
2017-06-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): On or about 4/5/2017, at the above addressed worksite, the employer did not make sure that equipment was inspected before use resulting in employees' exposure to electrical hazards, as evidenced by, among other conditions; fans that lacked of a ground prong on its attachment plug and/or had cord with broken outer insulation were used at the finishing department; a saw had been used with its cord outer insulation broken at the finishing department; and an electrical extension cord lacked of strain relief at the female end attachment plug at the laminating department. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100212 A01 |
Issuance Date |
2017-06-16 |
Current Penalty |
5855.5 |
Initial Penalty |
8365.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about 4/5/2017, at the finishing department of the above addressed worksite, an employee was exposed to a caught by hazard while working with a sanding machine that lacked guards on in-running rolls. Bluewater Sportfishing Boats Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 497598, citation number 1, item number 1 and was affirmed as a final order on 7/24/2012, with respect to a workplace located at 2901 Industrial Avenue 3, Fort Pierce, FL 34946. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19100037 B02 |
Issuance Date |
2017-06-16 |
Current Penalty |
469.2 |
Initial Penalty |
782.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": On or about 4/5/2017, at the lamination department of the above addressed worksite, exits were not marked exposing employees working in the area to a fire hazard. |
|
Citation ID |
03002A |
Citaton Type |
Other |
Standard Cited |
19100179 G01 V |
Issuance Date |
2017-06-16 |
Abatement Due Date |
2017-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions: On or about 4/5/2017, at the lamination department of the above addressed worksite, an employee was exposed to a struck-by hazard while operating a pendant control box for a hoisting mechanism whose push button were not marked. |
|
Citation ID |
03002B |
Citaton Type |
Other |
Standard Cited |
19100179 J02 |
Issuance Date |
2017-06-16 |
Abatement Due Date |
2017-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(j)(2): The following items were not be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: On or about 4/5/2017, at the lamination department, frequent inspections of a crane were not conducted for identifying defects, including but not limited to; missing latches and/or deformations of hooks, and/or excessive wear of operating components. |
|
Citation ID |
03003 |
Citaton Type |
Other |
Standard Cited |
19100242 A |
Issuance Date |
2017-06-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: On or about 4/5/2017, at the finishing department of the above addressed worksite, an air hose was repaired with tape, exposing employees to a struck by hazard. |
|
Citation ID |
03004 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 |
Issuance Date |
2017-06-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about 4/5/2017, at the lamination department of the above addressed worksite, an electrical panel board was blocked, exposing an employee to a struck by hazard. |
|
|
334975984
|
0418800
|
2012-07-02
|
2901 INDUSTRIAL AVENUE 3, FORT PIERCE, FL, 34946
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-07-02
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2012-09-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2012-07-10 |
Abatement Due Date |
2012-07-19 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2012-07-24 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about 7/2/2012, at the assembly department, Bluewater Sportfishing Boats Inc., Fort Pierce, FL. (a) An employee was exposed to a caught by hazard while working with a drill press (Sears Craftman, 15") that lacked a guard on its point of operation. (b) An employee was exposed to a caught by hazard while working with a table saw (Unisaw Delta Rockwell) that lacked a guard over the portion of the blade above the table and above the material being cut. Note: Certification of abatement must be submitted for this citation item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2012-07-10 |
Current Penalty |
800.0 |
Initial Penalty |
1020.0 |
Final Order |
2012-07-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) On or about 7/2/2012, at the assembly department, Bluewater Sportfishing Boats Inc., Fort Pierce, FL. An employee was exposed to a struck by hazard while working with a drill press (Sears Craftman, 15") that was not anchored. |
|
|
305500993
|
0418800
|
2002-09-03
|
2901 INDUSTRIAL AVE. 3, FORT PIERCE, FL, 34946
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2002-09-03
|
Case Closed |
2002-09-18
|
Related Activity
Type |
Complaint |
Activity Nr |
203575022 |
Safety |
Yes |
|
|