Search icon

CRUZ FRAMING INC - Florida Company Profile

Company Details

Entity Name: CRUZ FRAMING INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

CRUZ FRAMING INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 06 Jun 2022 (3 years ago)
Document Number: P22000046618
FEI/EIN Number 36-5024197

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 550 MARY ESTHER CUT OFF NW UNIT 18, SUITE 380, FORT WALTON BEACH, FL, 32548
Mail Address: 550 MARY ESTHER CUT OFF NW UNIT 18, SUITE 380, FORT WALTON BEACH, FL, 32548
ZIP code: 32548
County: Okaloosa
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ORTIZ CRUZ ELEAZAR President 550 MARY ESTHER CUT OFF NW UNIT 18 # 380, FORT WALTON BEACH, FL, 32548
ORTIZ CRUZ ELEAZAR Agent 550 MARY ESTHER CUT OFF NW UNIT 18, FORT WALTON BEACH, FL, 32548

Documents

Name Date
ANNUAL REPORT 2024-04-29
ANNUAL REPORT 2023-03-31
Domestic Profit 2022-06-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347293458 0418600 2024-02-21 361 ALLEY OAK LANE LOT 15 THE BLUFFS AT LAFAYETTE, FREEPORT, FL, 32439
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-02-21
Emphasis N: FALL, P: FALL
Case Closed 2024-07-15

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-03-15
Current Penalty 3318.6
Initial Penalty 5531.0
Final Order 2024-04-10
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 361 Alleyoak Lane, Lot 15 The Bluffs at Lafayette, Freeport, Florida: On February 21, 2024, the employer allowed his employees to perform framing activities without fall protection exposing his employees to a fall hazard of 11 feet 9 inches to the ground below.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-03-15
Abatement Due Date 2024-03-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-10
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) At 361 Alleyoak Lane, Lot 15 The Bluffs at Lafayette, Freeport, Florida: On February 21, 2024, the employer allowed his employees to perform framing activities without first training his employees on the hazards associated with falls to include but not limited to setting up and inspecting fall protection exposing his employees to a fall hazard of 10 feet 9 inches to the ground below.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-03-15
Current Penalty 2212.2
Initial Penalty 3687.0
Final Order 2024-04-10
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At 361 Alleyoak Lane, Lot 15 The Bluffs at Lafayette, Freeport, Florida: On February 21, 2024, the employer allowed his employees to use an extension ladder to gain access to the second level of the house and the rails of the ladder did not extend at least three feet above the wall landing to provide safe access exposing his employees to a fall hazard of 10 feet to the ground below.