Search icon

STAR ROOFING PROS INC - Florida Company Profile

Company Details

Entity Name: STAR ROOFING PROS INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation

STAR ROOFING PROS INC is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock.
In Florida, Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 04 Jan 2022 (3 years ago)
Date of dissolution: 22 Sep 2023 (a year ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2023 (a year ago)
Document Number: P22000002042
Address: 10911 N HYACINTH AVE, TAMPA, FL 33612
Mail Address: 10911 N HYACINTH AVE, TAMPA, FL 33612
ZIP code: 33612
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
IZAGUIRRE ROMERO, MARTHA C Agent 10911 N HYACINTH AVE, TAMPA, FL 33612
IZAGUIRRE ROMERO, MARTHA President 10911 N HYACINTH AVE, TAMPA, FL 33612

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2023-09-22 - -

Documents

Name Date
Domestic Profit 2022-01-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346316334 0420600 2022-11-01 4962 DISTRIBUTION DR, TAMPA, FL, 33605
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-11-01
Emphasis L: FORKLIFT, L: FALL, P: FALL
Case Closed 2023-04-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260602 D
Issuance Date 2023-01-17
Abatement Due Date 2023-03-06
Current Penalty 2143.2
Initial Penalty 3572.0
Final Order 2023-01-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck and as referenced by the note contained in 1926.602(d): a. At the jobsite located at 4962 Distribution Dr., Tampa, Florida: On or about November 1, 2022, the employer failed to ensure that employees, operating the Terex - Rough Terrain powered industrial truck to lift roof materials and the wood trash hopper for disposal of roof debris, were trained and evaluated on the safe operation.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2023-01-17
Abatement Due Date 2023-03-06
Current Penalty 3750.0
Initial Penalty 6250.0
Final Order 2023-01-27
Nr Instances 1
Nr Exposed 13
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking / working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: a. At the job-site located at 4962 Distribution Dr., Tampa, Florida: On or about November 1, 2022, employees were exposed to fall hazards of 25-feet while working on the roof of an industrial structure with steel roof deck, performing insulation and thermoplastic polyolefin (TPO) removal and installation. The roof had a 1:12 pitch; 25-feet to the eave. There were no guardrails, safety net, positioning devices, fall restraint systems or personal fall arrest system.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260761 B
Issuance Date 2023-01-17
Abatement Due Date 2023-03-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-01-27
Nr Instances 1
Nr Exposed 13
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.761(b): The employer did not train each employee exposed to a fall hazard in accordance with the requirements of 29 CFR 1926.761: a. At the job-site located at 4962 Distribution Dr., Tampa, Florida: On or about November 1, 2022, employees were exposed to fall hazards of 25-feet while working on the roof of an industrial structure with steel roof deck, performing insulation and thermoplastic polyolefin (TPO) removal and installation. Employees were not instructed in the recognition and identification of fall hazards in the work area, the procedures to be followed to prevent falls to lower levels and the fall protection requirements for steel erection.