Search icon

SANDY RENOVATIONS INC

Company Details

Entity Name: SANDY RENOVATIONS INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Inactive
Date Filed: 17 Nov 2021 (3 years ago)
Date of dissolution: 24 May 2023 (2 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 24 May 2023 (2 years ago)
Document Number: P21000098359
FEI/EIN Number APPLIED FOR
Address: 205 MARLER ST NW, APT 6, FORT WALTON BEACH, FL 32548
Mail Address: 205 MARLER ST NW, APT 6, FORT WALTON BEACH, FL 32548
ZIP code: 32548
County: Okaloosa
Place of Formation: FLORIDA

Agent

Name Role Address
FLORES PALMA, ELVIN A Agent 205 MARLER ST NW, APT 6, FORT WALTON BEACH, FL 32548

President

Name Role Address
FLORES PALMA, ELVIN A President 205 MARLER ST NW APT 6, FORT WALTON BEACH, FL 32548

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2023-05-24 No data No data

Documents

Name Date
VOLUNTARY DISSOLUTION 2023-05-24
ANNUAL REPORT 2023-03-08
ANNUAL REPORT 2022-03-16
Domestic Profit 2021-11-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346152564 0418600 2022-08-17 13646 FRONT BEACH ROAD LOT 5 AND LOT 6 MARGARITAVILLE, PANAMA CITY BEACH, FL, 32413
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-08-17
Emphasis L: FALL, P: FALL
Case Closed 2023-06-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2022-08-23
Abatement Due Date 2022-09-02
Current Penalty 2486.0
Initial Penalty 2486.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a) At 13646 Front Beach Road, Unit 5 & 6 Margaritaville, Panama City Beach, Florida: On August 17, 2022 ; the employer failed to ensure employees operating pneumatic nail guns while performing framing activities were using eye protection exposing his employees to struck-by hazards.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2022-08-23
Abatement Due Date 2022-09-02
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) At 13646 Front Beach Road, Unit 6 Margaritaville, Panama City Beach, Florida: On August 17, 2022; the employer failed to ensure a scaffold platform measured 18 inches wide as required by the standard for an employee involved in framing activities from a job made scaffold exposing his employees to a fall hazard of 17 feet 2 inches to the ground below.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2022-08-23
Abatement Due Date 2022-09-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) At 13646 Front Beach Road, Unit 6 Margaritaville, Panama City Beach, Florida: On August 17, 2022; the employer failed to ensure employee(s) involved in framing activities from a job made scaffold were using fall protection exposing his employees to a fall hazard of 17 feet 2 inches to the ground below.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2022-08-23
Abatement Due Date 2022-09-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) At 13646 Front Beach Road, Unit 6 Margaritaville, Panama City Beach, Florida: On August 17, 2022; the employer allowed his employee to perform framing activities from a job made scaffold without first ensuring the employee was trained on the hazards of scaffolding to include but not limited to the use of fall protection and how wide scaffold are required to be exposing his employees to a fall hazard of 17 feet 2 inches to the ground below.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2022-08-23
Abatement Due Date 2022-09-02
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 13646 Front Beach Road, Unit 5 Margaritaville, Panama City Beach, Florida: On or about August 17, 2022 and at times prior; the employer failed to ensure employees involved in framing activities were using fall protection exposing his employees to a fall hazard of up to 21 feet 11 inches to the ground below.
346118409 0418600 2022-07-20 8855 EAST COUNTY HIGHWAY 30A, PANAMA CITY, FL, 32413
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2022-07-20
Emphasis L: FALL
Case Closed 2023-06-29

Related Activity

Type Accident
Activity Nr 1922163
Type Inspection
Activity Nr 1609124
Safety Yes
Type Inspection
Activity Nr 1609870
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2022-12-19
Current Penalty 4786.0
Initial Penalty 4786.0
Final Order 2023-02-21
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) 8855 East County Highway 30A, Panama City FL. On or about July 20, 2022, and at times prior to, the employer exposed an employee to electrical, struck-by, and fall hazards in that the employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials, and equipment.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2022-12-19
Current Penalty 4786.0
Initial Penalty 4786.0
Final Order 2023-02-21
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) At 8855 East County Highway 30A, Panama City, Florida: On or about July 20, 2022 and at times prior; employee was exposed to fall hazards, while performing framing activities at heights greater than 30 feet without fall protection training.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2022-12-19
Current Penalty 4786.0
Initial Penalty 4786.0
Final Order 2023-02-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a):The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: a) At 8855 East County Highway 30A, Panama City, Florida: On or about July 20, 2022 and at times prior; employee was exposed to fall hazards, while performing framing activities from a 6 ft. Werner A-frame ladder without ladder training.

Date of last update: 12 Feb 2025

Sources: Florida Department of State