Entity Name: | LIZ SMART CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Profit Corporation
LIZ SMART CONSTRUCTION INC is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 25 Oct 2021 (3 years ago) |
Date of dissolution: | 01 Apr 2024 (a year ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 01 Apr 2024 (a year ago) |
Document Number: | P21000092090 |
FEI/EIN Number |
87-3406879
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 6710 COLLINGS RD, 306, JACKSONVILLE, FL 322445873 |
Mail Address: | 6710 COLLINGS RD, 306, JACKSONVILLE, FL 322445873 |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Escalante Colindres, Carlos R | Agent | 365 W Oliver St, 306, Baldwin, FL 32234 |
VALLADARES MARTINEZ, DAMARY A | Vice President | 6710 COLLINGS RD, 306 JACKSONVILLE, FL 322445873 |
GARCIA, JACOB OMAR | President | 6710 COLLINGS RD, 306 JACKSONVILLE, FL 322445873 |
ESCALANTE COLINDRES, CARLOS R | Owner | 365 W Oliver St, Jacksonville, FL 32234 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2024-04-01 | - | - |
REGISTERED AGENT NAME CHANGED | 2023-07-11 | Escalante Colindres, Carlos R | - |
REGISTERED AGENT ADDRESS CHANGED | 2023-07-11 | 365 W Oliver St, 306, Baldwin, FL 32234 | - |
CHANGE OF PRINCIPAL ADDRESS | 2022-09-19 | 6710 COLLINGS RD, 306, JACKSONVILLE, FL 322445873 | - |
CHANGE OF MAILING ADDRESS | 2022-09-19 | 6710 COLLINGS RD, 306, JACKSONVILLE, FL 322445873 | - |
Name | Date |
---|---|
VOLUNTARY DISSOLUTION | 2024-04-01 |
AMENDED ANNUAL REPORT | 2023-07-11 |
ANNUAL REPORT | 2023-06-07 |
AMENDED ANNUAL REPORT | 2022-10-24 |
ANNUAL REPORT | 2022-09-19 |
Domestic Profit | 2021-10-25 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346782576 | 0419700 | 2023-06-21 | 9104 JOANNES WAY LOT 27, JACKSONVILLE, FL, 32222 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2023-07-12 |
Current Penalty | 2812.8 |
Initial Penalty | 4688.0 |
Final Order | 2023-08-02 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On a 5:12 picthed roof of a temporary residential new construction worksite, located at 9104 Joannes Way - Lot 27: On or about June 21, 2023, the employer exposed an employee to fall hazards ranging from 8 feet to 16-feet 8 inches, in that fall protection was not utilized by the employee while installing underlayment paper. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19261053 B01 |
Issuance Date | 2023-07-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-08-02 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: a. On a temporary residential work site located at 9104 Joannes Way - Lot 27, Jacksonville, FL 32222: On or about June 21, 2023, the employer exposed an employee to fall hazards, in that the ladder's side rails did not extend at least 3 feet above the roof. The employee was being exposed to fall hazards. |