Entity Name: | CALLAGHAN ROOFING INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
CALLAGHAN ROOFING INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 16 Sep 2021 (4 years ago) |
Date of dissolution: | 23 Sep 2022 (3 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 23 Sep 2022 (3 years ago) |
Document Number: | P21000081776 |
Address: | 27 ZION HILL ROAD, CRAWFORDVILLE, FL, 32327 |
Mail Address: | 27 ZION HILL ROAD, CRAWFORDVILLE, FL, 32327 |
ZIP code: | 32327 |
County: | Wakulla |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
CALLAGHAN JASON J | President | 27 ZION HILL ROAD, CRAWFORDVILLE, FL, 32327 |
CALLAGHAN JASON J | Secretary | 27 ZION HILL ROAD, CRAWFORDVILLE, FL, 32327 |
CALLAGHAN JASON J | Vice President | 27 ZION HILL ROAD, CRAWFORDVILLE, FL, 32327 |
CALLAGHAN JASON J | Treasurer | 27 ZION HILL ROAD, CRAWFORDVILLE, FL, 32327 |
CALLAGHAN JASON J | Agent | 27 ZION HILL ROAD, CRAWFORDVILLE, FL, 32327 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2022-09-23 | - | - |
Name | Date |
---|---|
Domestic Profit | 2021-09-16 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342510047 | 0419700 | 2017-07-31 | 2530 ULYSSES ROAD, TALLAHASSEE, FL, 32312 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2017-08-10 |
Current Penalty | 831.0 |
Initial Penalty | 1385.0 |
Final Order | 2017-09-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a. On or about July 31, 2017, while performing roofing operations, two employees using Bostich pneumatic nail guns were not protected from nails or flying debris by use of ANSI 87.1 safety glasses. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-08-10 |
Current Penalty | 1303.8 |
Initial Penalty | 2173.0 |
Final Order | 2017-09-18 |
Nr Instances | 2 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. On or about July 31, 2017, on the south side of a 6:12 pitch roof, three employees performing roofing operations were not protected from a 10-foot 7-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection. b. On or about July 31, 2017, on the north side of a 6:12 pitch roof, an employee performing roofing operations was not protected from a 11-foot 7-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2017-08-10 |
Current Penalty | 1108.2 |
Initial Penalty | 1847.0 |
Final Order | 2017-09-18 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about July 31, 2017, four employees used a 24-foot Werner extension ladder to access a roof improperly, in that the ladder was not extended 3 feet over the eave nor was it secured from slippage, exposing employees to a fall hazard. |
Date of last update: 02 Apr 2025