Entity Name: | MAYAS KEY CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
MAYAS KEY CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 11 Aug 2021 (4 years ago) |
Date of dissolution: | 22 Sep 2023 (2 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 22 Sep 2023 (2 years ago) |
Document Number: | P21000072215 |
FEI/EIN Number |
87-2201482
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5960 WALLACE DR, ORLANDO, FL, 32807, US |
Mail Address: | 5960 WALLACE DR, ORLANDO, FL, 32807, US |
ZIP code: | 32807 |
County: | Orange |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ROSALES ERAZO FRANCIA N | President | 5960 WALLACE DR, ORLANDO, FL, 32807 |
ROSALES ERAZO FRANCIA N | Agent | 5960 WALLACE DR, ORLANDO, FL, 32807 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2023-09-22 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2022-03-04 |
Domestic Profit | 2021-08-11 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345955793 | 0419700 | 2022-05-09 | 839 TERRAPIN DRIVE, DEBARY, FL, 32713 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1891828 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2022-07-12 |
Current Penalty | 3315.0 |
Initial Penalty | 3315.0 |
Final Order | 2022-08-09 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide: a. At the residential construction job site, on the second level of the scaffold system, at 839 Terrapin Drive in Debary Florida. On or about May 6, 2022, and at times prior, three stucco masonry employees were exposed to a 13.4-foot fall hazard in that two scaffold planks were missing, creating a 1.6-foot wide gap at each end of the scaffold deck that the employees could fall between. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G04 I |
Issuance Date | 2022-07-12 |
Current Penalty | 3315.0 |
Initial Penalty | 3315.0 |
Final Order | 2022-08-09 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a. At the residential construction job site, on the second level of the scaffold system, at 839 Terrapin Drive in Debary Florida. On or about May 6, 2022, and at times prior, three stucco masonry employees were exposed to a 13.4-foot fall hazard in that end rails were not installed at each end of the decking. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2022-07-12 |
Current Penalty | 3315.0 |
Initial Penalty | 3315.0 |
Final Order | 2022-08-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. At the residential construction job site, on the front porch roof, at 839 Terrapin Drive in Debary Florida. On or about May 6, 2022, a stucco masonry employee was exposed to an 11-foot fall hazard from the eave of the 4:12 pitch roof in that he wasn't protected by a fall protection system. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B06 |
Issuance Date | 2022-07-12 |
Current Penalty | 5801.0 |
Initial Penalty | 5801.0 |
Final Order | 2022-08-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(6): Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement. a. At the residential construction job site, on the front porch roof, at 839 Terrapin Drive in Debary Florida. On or about May 6, 2022, a stucco masonry employee was exposed to an 21-foot fall hazard from the extension ladder that was placed on the 4:12 pitch roof without tie-offs, fasteners, or cleats. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State