Search icon

LACOSTA REMODELING, INC. - Florida Company Profile

Company Details

Entity Name: LACOSTA REMODELING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

LACOSTA REMODELING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 16 Mar 2021 (4 years ago)
Document Number: P21000026366
FEI/EIN Number 86-3109618

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5327 SW 75TH TERRACE, GAINESVILLE, FL, 32608, US
Mail Address: 5327 SW 75TH TERRACE, GAINESVILLE, FL, 32608, US
ZIP code: 32608
County: Alachua
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ACOSTA - VARGAS LINO President 5327 SW 75TH TERRACE, GAINESVILLE, FL, 32608
ACOSTA - VARGAS LINO Director 5327 SW 75TH TERRACE, GAINESVILLE, FL, 32608
ACOSTA - VARGAS AMANDA Secretary 5327 SW 75TH TERRACE, GAINESVILLE, FL, 32608
ACOSTA -VARGAS LINO Agent 5327 SW 75TH TERRACE, GAINESVILLE, FL, 32608

Documents

Name Date
ANNUAL REPORT 2024-02-10
ANNUAL REPORT 2023-04-19
ANNUAL REPORT 2022-04-01
Domestic Profit 2021-03-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347158966 0419730 2023-12-12 2810 W. LESTER ROAD, APOPKA, FL, 32712
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-12-12
Emphasis N: FALL, P: FALL
Case Closed 2024-03-12

Related Activity

Type Inspection
Activity Nr 1716550
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2024-02-07
Current Penalty 2765.0
Initial Penalty 2765.0
Final Order 2024-03-11
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns. a. On or about December 12, 2023, at O2B Apopka, employees were exposed to struck-by hazards, in that the use of head protection was not enforced by the employer while employees were engaged in framing activities above.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-02-07
Current Penalty 4839.0
Initial Penalty 4839.0
Final Order 2024-03-11
Nr Instances 2
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a. On or about December 12, 2023, at O2B Apopka, employees were exposed to 12-feet 8-inch fall hazards while conducting framing work activities, in that, fall protection was not used. b. On or about December 12, 2023, at O2B Apopka, employees were exposed to 13-feet 7-inches fall hazards while conducting framing work activities, in that, fall protection was not used.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2024-02-07
Abatement Due Date 2024-03-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-03-11
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. On or about December 12, 2023, at O2B Apopka, the employer did not have fall protection training certificates for employees exposed to fall hazards while conducting framing activities.