Entity Name: | L & R UNDERGROUND SOLUTIONS, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
L & R UNDERGROUND SOLUTIONS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 05 Mar 2021 (4 years ago) |
Document Number: | P21000023357 |
FEI/EIN Number |
86-2692944
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2167 KEYSTONE AVE., ST CLOUD, FL, 34772 |
Mail Address: | 2167 KEYSTONE AVE., ST CLOUD, FL, 34772 |
ZIP code: | 34772 |
County: | Osceola |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
REX NICHOLAS K | President | 2167 KEYSTONE AVE, ST CLOUD, FL, 34772 |
REX NICHOLAS K | Agent | 2167 KEYSTONE AVE, ST CLOUD, FL, 34772 |
Name | Date |
---|---|
AMENDED ANNUAL REPORT | 2024-07-08 |
ANNUAL REPORT | 2024-02-26 |
ANNUAL REPORT | 2023-03-15 |
ANNUAL REPORT | 2022-02-03 |
Domestic Profit | 2021-03-05 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346859531 | 0420600 | 2023-07-26 | BIG SKY AND GAVIN SKY DR., KISSIMMEE, FL, 34744 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Accident |
Activity Nr | 2062767 |
Type | Referral |
Activity Nr | 2059360 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1689443 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1701018 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260021 B02 |
Issuance Date | 2024-01-22 |
Abatement Due Date | 2024-03-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-02-20 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 7/25/2023, at the job site, employees working near electrical equipment were not trained to be able to recognize electrical hazards. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260950 B01 I |
Issuance Date | 2024-01-22 |
Abatement Due Date | 2024-03-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-02-20 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.950(b)(1)(i): Each employee was not trained in, and familiar with, the safety-related work practices, safety procedures, and other safety requirements in this subpart that pertain to his or her job assignments. a) On or about 07/25/2023, at the job site, employees working near electrical equipment had not received any instruction/training on electrical safety work practices. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260960 B01 I |
Issuance Date | 2024-01-22 |
Abatement Due Date | 2024-03-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-02-20 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.960(b)(1)(i): Unqualified employees worked on and/or with exposed energized lines and/or parts of equipment. a) On or about 07/25/2023, at the job site, employees working on or near the electrical switch box were not qualified, exposing themselves to a 14,000 volts electrical hazard. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260960 B02 |
Issuance Date | 2024-01-22 |
Abatement Due Date | 2024-03-01 |
Current Penalty | 4355.1 |
Initial Penalty | 4839.0 |
Final Order | 2024-02-20 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.960(b)(2): Electric lines and equipment were not considered or treated as energized when they had not been de-energized in accordance with 1926.961. a) On or about 07/25/2023, at the job site, the employees working on or near the electrical switch box did not de-energize the live parts, exposing employees to a 14,000 volts electrical hazard. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260960 C01 III |
Issuance Date | 2024-01-22 |
Abatement Due Date | 2024-03-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-02-20 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.960(c)(1)(iii): The employer did not ensure that no employee approaches or takes any conductive object closer to exposed energized parts than the employer's established minimum approach distance, unless the measures outlined in 1926.960(c)(1)(iii)(A) - (C) were met: a) On or about 07/25/2023, at the job site, employees working on or near the electrical switch box did not de-energize the live parts, and were within the minimum approach distance, exposing themselves to a 14,000 volts electrical hazard. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260952 A01 |
Issuance Date | 2024-01-22 |
Abatement Due Date | 2024-03-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-02-20 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.952(a)(1): In assigning an employee or a group of employees to perform a job, the employer did not provide the employee in charge of the job with all available information that relates to the determination of existing characteristics and conditions required by � 1926.950(d). a) On or about 07/25/2023, at the job site, employees working on or near the electrical switch box did not conduct a job briefing prior to work. |