Entity Name: | ENR REMODELING SOLUTIONS INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
ENR REMODELING SOLUTIONS INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 08 Jan 2021 (4 years ago) |
Last Event: | AMENDMENT |
Event Date Filed: | 27 Dec 2021 (3 years ago) |
Document Number: | P21000004839 |
FEI/EIN Number |
86-1755074
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 9017 MONTEVELLO CT, ORLANDO, FL, 32818, US |
Mail Address: | 9017 MONTEVELLO CT, ORLANDO, FL, 32818, US |
ZIP code: | 32818 |
County: | Orange |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
AMADOR MICHAEL | President | 9017 MONTEVELLO CT, ORLANDO, FL, 32818 |
AMADOR MICHAEL | Agent | 9017 MONTEVELLO CT, ORLANDO, FL, 32818 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
AMENDMENT | 2021-12-27 | - | - |
REGISTERED AGENT NAME CHANGED | 2021-12-27 | AMADOR, MICHAEL | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-19 |
ANNUAL REPORT | 2023-03-08 |
ANNUAL REPORT | 2022-03-21 |
Amendment | 2021-12-27 |
Domestic Profit | 2021-01-08 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347799306 | 0419730 | 2024-10-02 | 15951 GEM VIEW ST. LOT 242, WINTER GARDEN, FL, 34787 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1779095 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260095 D01 |
Issuance Date | 2024-10-22 |
Abatement Due Date | 2024-11-18 |
Current Penalty | 4610.0 |
Initial Penalty | 4610.0 |
Final Order | 2024-11-18 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.95(d)(1): Except as provided by paragraphs (d)(2) through (d)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, was not provided by the employer at no cost to employee(s). a. On or about October 02, 2024, at a residential construction site Lot 242: the employer did not provide the necessary PPE at no cost to the employees (fall, eye and head protection) while conducting framing activities, exposing employees to falls hazards. Employees purchased their own personal protective equipment, and it was not maintained by the employer. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-10-22 |
Abatement Due Date | 2024-11-18 |
Current Penalty | 6452.0 |
Initial Penalty | 6452.0 |
Final Order | 2024-11-18 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a. On or about October 02, 2024, at a residential construction site Lot 242: employees were exposed to 10-foot 2-inch fall hazards while installing trusses, in that a fall protection system was not used/enforced. b. On or about October 02, 2024, at a residential construction site Lot 242: employees were exposed to 9-foot 6-inch fall hazards while installing trusses, in that a fall protection system was not used/enforced. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 B01 |
Issuance Date | 2024-10-22 |
Abatement Due Date | 2024-11-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-11-18 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. On or about October 02, 2024, at a residential construction site Lot 242: the employer did not prepare and maintain a written fall protection training program certification for employees exposed to fall hazards of 10 feet 2 inches while working on trusses. |