Entity Name: | J & B ROOFPROS INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
J & B ROOFPROS INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 05 Nov 2020 (4 years ago) |
Last Event: | AMENDMENT |
Event Date Filed: | 24 Jun 2021 (4 years ago) |
Document Number: | P20000088937 |
FEI/EIN Number |
85-3995044
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2420 NE 6TH AVE, POMAPNO BEACH, FL, 33064, US |
Mail Address: | 2420 NE 6TH AVE, POMAPNO BEACH, FL, 33064, US |
ZIP code: | 33064 |
County: | Broward |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
VELASQUEZ KARINA ODALY | President | 2420 NE 6TH AVE, POMPANO BEACH, FL, 33064 |
BARBOSA BRADS | Vice President | 2420 NE 6TH AVE, POMAPNO BEACH, FL, 33064 |
VELASQUEZ KARINA ODALY | Agent | 2420 NE 6TH AVE, POMAPANO BEACH, FL, 33064 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2022-03-10 | 2420 NE 6TH AVE, E, POMAPNO BEACH, FL 33064 | - |
AMENDMENT | 2021-06-24 | - | - |
CHANGE OF MAILING ADDRESS | 2021-05-19 | 2420 NE 6TH AVE, E, POMAPNO BEACH, FL 33064 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-25 |
ANNUAL REPORT | 2023-03-20 |
ANNUAL REPORT | 2022-03-10 |
Amendment | 2021-06-24 |
ANNUAL REPORT | 2021-05-19 |
Domestic Profit | 2020-11-05 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347434193 | 0418800 | 2024-04-24 | 11672 NW 20TH AVE., CORAL SPRINGS, FL, 33071 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-04-24 |
Current Penalty | 3457.0 |
Initial Penalty | 3457.0 |
Final Order | 2024-10-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about April 24, 2024, at 11672 NW 20th Ave. Coral Springs FL, an employee was engaged in roofing work at a residential apartment complex roof with a slope of 6:12 was exposed to a fall hazard of approximately 25-feet above ground level without a means of fall protection. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 B01 |
Issuance Date | 2024-04-24 |
Abatement Due Date | 2024-05-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-10-29 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record. a) On or about April 24, 2024, at 11672 NW 20th Ave. Coral Springs FL, the employer did not maintain fall protection training certifications for employees exposed to fall hazards when working from elevations. |