Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-04-27
|
Emphasis |
L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2022-06-08
|
Related Activity
Type |
Referral |
Activity Nr |
1807865 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100101 B |
Issuance Date |
2021-09-09 |
Abatement Due Date |
2021-10-05 |
Current Penalty |
2340.0 |
Initial Penalty |
2340.0 |
Final Order |
2021-10-05 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gasses in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks was not in accordance with Compressed Gas Association Pamphlet P-1-1965: a. At the facility located at 1125 Cranleigh Ave, in Deland, Florida: On or about April 14, 2021, the employer exposed employees to struck-by and fire hazards, in that the employer allowed six unprotected, propane filled cylinders, to be openly stored in close proximity of forklift traffic (heavy objects) that could strike the cylinders. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100106 E06 I |
Issuance Date |
2021-09-09 |
Current Penalty |
5461.0 |
Initial Penalty |
5461.0 |
Final Order |
2021-10-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat: a. At the facility located at 1125 Cranleigh Ave, in Deland, Florida; On or about, March 20, 2021, the employer exposed employees to burn hazards, in that the employer did not take adequate precautions to prevent the ignition of flammable vapors, as the employer allowed employees to make homemade personal fire/warmth buckets in the work area, which included the hazardous ignition of flammable vapors, such as, but not limited to, alcohol. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2021-09-09 |
Abatement Due Date |
2021-10-05 |
Current Penalty |
2340.0 |
Initial Penalty |
2340.0 |
Final Order |
2021-10-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a. At the facility located at 1125 Cranleigh Ave, in Deland, Florida: On or about April 14, 2021, the employer exposed employees to struck-by and crushing hazards, in that, the Dayton manual drill was not anchored to anchored to prevent walking or moving during drilling operations. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040033 A |
Issuance Date |
2021-09-09 |
Current Penalty |
780.0 |
Initial Penalty |
780.0 |
Final Order |
2021-10-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.33(a): The OSHA 300 Log, the privacy case list (if one exists), the annual summary, and the OSHA 301 Incident Report forms were not saved for five (5) years following the end of the calendar year that these records covered: a. At the facility located at 1125 Cranleigh Ave, in Deland, Florida; On or about April 14, 2021, the employer did not keep previous OSHA 300 records for calendar years 2016 to the present. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2021-09-09 |
Current Penalty |
3901.0 |
Initial Penalty |
3901.0 |
Final Order |
2021-10-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye: a. On or about March 21, 2021, the employer did not report to OSHA within 24 hours, the in-patient hospitalization of an employee who sustained a work related injury. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100157 G01 |
Issuance Date |
2021-09-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-05 |
Nr Instances |
1 |
Nr Exposed |
20 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(g)(1): Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer did not provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a. At the facility located at 1125 Cranleigh Ave, in Deland, Florida; On or about April 14, 2021, the employer exposed employees to hazards related to fire, in that employees were exposed to extinguish incipient fires, but were not provided with fire extinguisher training for incipient stage fire fighting. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100178 L01 I |
Issuance Date |
2021-09-09 |
Abatement Due Date |
2021-10-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-05 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer had not ensured that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in paragraph (l): a. At this facility located at 1125 Cranleigh Ave, Deland, Florida; On or about April 14, 2021, the employer exposed employees to struck-by and crushing hazards, when employees were allowed to operate powered industrial forklifts without first completing the training required by this standard. |
|
Citation ID |
02005A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2021-09-09 |
Abatement Due Date |
2021-10-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-05 |
Nr Instances |
1 |
Nr Exposed |
20 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. At this facility, located at 1125 Cranleigh Ave, Deland, Florida; On or about April 14, 2021, the employer had not developed nor maintained a written hazard communication program consisting of a written program, SDS sheet and employee training for chemicals used in the workplace for chemicals such as but not limited to denatured alcohol, propane, argon, acetylene, etc. |
|
Citation ID |
02005B |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2021-09-09 |
Abatement Due Date |
2021-10-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-05 |
Nr Instances |
1 |
Nr Exposed |
20 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1):Employees were not provided information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area: a. At this facility located at 1125 Cranleigh Ave, Deland, Florida; On or about April 14, 2021, the employer did not provide information and training to all employees working with various chemicals such as but not limited to denatured alcohol, propane, acetylene, oxygen, etc. at the time of their initial assignment, exposing employees to burns and health hazards. |
|
|