Entity Name: | STORM PEAK ROOFING INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
STORM PEAK ROOFING INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 02 Apr 2020 (5 years ago) |
Document Number: | P20000027744 |
FEI/EIN Number |
85-1418421
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 220 South Safford Avenue, TARPON SPRINGS, FL, 34689, US |
Mail Address: | 220 South Safford Avenue, TARPON SPRINGS, FL, 34689, US |
ZIP code: | 34689 |
County: | Pinellas |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
GIBSON WESLEY A | President | 912 GAINESWAY DR, TARPON SPRINGS, FL, 34689 |
GIBSON WESLEY A | Agent | 912 GAINESWAY DR., TARPON SPRINGS, FL, 34689 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2022-02-01 | 220 South Safford Avenue, TARPON SPRINGS, FL 34689 | - |
CHANGE OF MAILING ADDRESS | 2022-02-01 | 220 South Safford Avenue, TARPON SPRINGS, FL 34689 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-02-13 |
ANNUAL REPORT | 2024-02-26 |
ANNUAL REPORT | 2023-03-15 |
ANNUAL REPORT | 2022-02-01 |
ANNUAL REPORT | 2021-01-23 |
Domestic Profit | 2020-04-02 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347321291 | 0420600 | 2024-03-05 | 3600 MAGNOLIA RIDGE CIRCLE, PALM HARBOR, FL, 34684 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 2136243 |
Safety | Yes |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2022-09-17 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2023-07-17 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260502 H01 V |
Issuance Date | 2022-12-05 |
Abatement Due Date | 2022-12-15 |
Current Penalty | 2175.5 |
Initial Penalty | 4351.0 |
Final Order | 2022-12-30 |
Nr Instances | 1 |
Nr Exposed | 5 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 1926.502(h)(1)(v) The safety monitor had other responsibilities which could take the monitor's attention from the monitoring function: a) On the site located at 4801 W Leona St, Tampa FL: On or about 9/17/2022 the employer exposed employees to fall hazards, in that fall protection was not provided to employees while they were conducting roofing activities on a 4:12 pitch roof without the use of fall protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261060 A01 III |
Issuance Date | 2022-12-05 |
Abatement Due Date | 2022-12-15 |
Current Penalty | 2175.5 |
Initial Penalty | 4351.0 |
Final Order | 2022-12-30 |
Nr Instances | 2 |
Nr Exposed | 5 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 1926.1060(a)(1)(iii) The employer did not ensure that each employee using ladders and stairways had been trained by a competent person in the proper construction, use, placement, and care in handling of all stairways and ladders: a.) At a residence, located at 4801 W Leona St, Tampa FL: On or about 9/17/2022 the employer exposed employees to fall hazards, in that the ladder in use to access the first roof from the ground did not have side rails extending at least 3 feet (.9 m) above the landing surface, the railings were approximately 2 feet above the roof edge. b.) At a residence, located at 4801 W Leona St, Tampa FL: On or about 9/17/2022 the employer exposed employees to fall hazards, in that the ladder in use from the first roof to the second roof landing did not have side rails extending at least 3 feet (.9 m) above the second roof landing surface, the railings were approximately 1 foot above the roof edge. |