Search icon

EVOLETH CONSTRUCTION, INC. - Florida Company Profile

Company Details

Entity Name: EVOLETH CONSTRUCTION, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

EVOLETH CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 16 Jan 2020 (5 years ago)
Date of dissolution: 27 Sep 2024 (7 months ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2024 (7 months ago)
Document Number: P20000019883
FEI/EIN Number 822955293

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2519 W. HIAWATHA ST, TAMPA, FL, 33614, US
Mail Address: 2519 W. HIAWATHA ST, TAMPA, FL, 33614, US
ZIP code: 33614
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
GARCIA WALTER N President 2519 W. HIAWATHA ST, TAMPA, FL, 33614
RODRIGUEZ ELISA Vice President 2519 W. HIAWATHA ST, TAMPA, FL, 33614
OUTSOURCE BUSINESS SOLUTIONS, LLC Agent -

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -
REGISTERED AGENT ADDRESS CHANGED 2023-05-01 5120 S FLORIDA AVE, SUITE 329, LAKELAND, FL 33813 -
REGISTERED AGENT NAME CHANGED 2021-10-20 OUTSOURCE BUSINESS SOLUTIONS LLC. -
REINSTATEMENT 2021-10-20 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2021-09-24 - -
CHANGE OF MAILING ADDRESS 2021-07-19 2519 W. HIAWATHA ST, TAMPA, FL 33614 -
CHANGE OF PRINCIPAL ADDRESS 2021-07-19 2519 W. HIAWATHA ST, TAMPA, FL 33614 -
CONVERSION 2020-01-16 - CORPORATION WAS A CONVERSION RESULT. CONVERTING CORPORATION WAS L17000202805. CONVERSION NUMBER 500000200675

Documents

Name Date
ANNUAL REPORT 2023-05-01
ANNUAL REPORT 2022-02-24
REINSTATEMENT 2021-10-20
Domestic Profit 2020-01-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344812060 0420600 2020-06-29 32203 MAHOGANY VALLEY DR., WESLEY CHAPEL, FL, 33543
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2020-06-29
Emphasis L: FALL
Case Closed 2022-03-01

Related Activity

Type Inspection
Activity Nr 1481200
Safety Yes
Type Inspection
Activity Nr 1481211
Safety Yes
Type Inspection
Activity Nr 1481890
Safety Yes
Type Inspection
Activity Nr 1481185
Safety Yes
Type Referral
Activity Nr 1610398
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2020-08-19
Current Penalty 2428.8
Initial Penalty 4048.0
Final Order 2020-09-15
Nr Instances 3
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about 06/29/2020, at 32203 Mahogany Valley Dr. - employees were exposed to an 11 feet 3 inch fall hazard while conducting carpentry work from the second floor of a new house, in that, guard rails were not installed and or fall protection was not used. b. On or about 06/29/2020, at 32203 Mahogany Valley Dr. - an employee was exposed to a 13 feet 3 inch fall hazard while seating on a window opening ledge to conduct carpentry work, in that, fall protection was not used. c. On or about 06/29/2020, at 32203 Mahogany Valley Dr. - employees were exposed to a 20 feet 3 inch fall hazard while conducting carpentry work from the roof of a 2-story house, in that, fall protection was not used.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A02
Issuance Date 2020-08-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-09-15
Nr Instances 3
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii) a. On or about 06/29/2020, at 32203 Mahogany Valley Dr. - employees were exposed to a 11 feet 3 inch fall hazard while conducting carpentry work from the second floor of a new house, in that, guard rails were not installed and or fall protection were not provided with training. b. On or about 06/29/2020, at 32203 Mahogany Valley Dr. - an employee was exposed to a 13 feet 3 inch fall hazard while seating on a window opening ledge to conduct carpentry work, in that, fall protection were not provided with training. c. On or about 06/29/2020, at 32203 Mahogany Valley Dr. - employees were exposed to a 20 feet 3 inch fall hazard while conducting carpentry work from 2 story house roof, in that, fall protection were not provided with training.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2020-08-19
Abatement Due Date 2020-09-15
Current Penalty 1735.2
Initial Penalty 2892.0
Final Order 2020-09-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about 06/29/2020, at 32203 Mahogany Valley Dr. - the rails of the ladder used to access the second floor of a new construction house did not extend at least 3 foot above the upper landing surface, exposing the employees to an 11 feet 3 inch fall hazard.
344805528 0420600 2020-06-25 SR 56 BETWEEN MEADOW POINTE BLVD. AND MORRIS BRIDGE RD., WESLEY CHAPEL, FL, 33543
Inspection Type Referral
Scope NoInspection
Safety/Health Safety
Close Conference 2020-06-25
Emphasis L: FALL
Case Closed 2020-09-15

Related Activity

Type Referral
Activity Nr 1610165
Safety Yes