Search icon

PRECISION PLUMBING GROUP, INC. - Florida Company Profile

Company Details

Entity Name: PRECISION PLUMBING GROUP, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

PRECISION PLUMBING GROUP, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 25 Feb 2020 (5 years ago)
Document Number: P20000018217
FEI/EIN Number 84-4947505

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2265 LAIRD RD., CRESTVIEW, FL, 32539, US
Mail Address: 2265 LAIRD RD., CRESTVIEW, FL, 32539, US
ZIP code: 32539
County: Okaloosa
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MOSELEY KATHERINE D Treasurer 2265 LAIRD RD., CRESTVIEW, FL, 32539
MOSELEY STEVEN C Agent 2265 LAIRD RD., CRESTVIEW, FL, 32539
MOSELEY STEVEN C President 2265 LAIRD RD., CRESTVIEW, FL, 32539
MOSELEY KATHERINE D Vice President 2265 LAIRD RD., CRESTVIEW, FL, 32539
MOSELEY KATHERINE D Secretary 2265 LAIRD RD., CRESTVIEW, FL, 32539

Documents

Name Date
ANNUAL REPORT 2025-01-09
ANNUAL REPORT 2024-01-09
ANNUAL REPORT 2023-01-20
ANNUAL REPORT 2022-02-01
ANNUAL REPORT 2021-01-31
Domestic Profit 2020-02-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345109599 0418600 2021-01-20 507 AMOS STREET, CRESTVIEW, FL, 32539
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2021-01-20
Emphasis L: FALL
Case Closed 2022-04-19

Related Activity

Type Referral
Activity Nr 1721440
Safety Yes
Type Inspection
Activity Nr 1510960
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2021-04-01
Abatement Due Date 2021-04-13
Current Penalty 2000.0
Initial Penalty 3511.0
Final Order 2021-04-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1):Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) At 507 Amos Street, Crestview, Florida: On or about January 12, 2021 and at times prior; the employer allowed his employee to transit a second floor walkway without guardrails installed or without any other type of fall protection exposing his employee to a fall hazard of 9 feet 9 inches to the ground below.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2021-04-01
Abatement Due Date 2021-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-04-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a) At 507 Amos Street, Crestview, Florida: On or about January 12, 2021 and at times prior; the employer exposed his employee to a fall hazard of 9 feet 9 inches to the ground below in that the employer did not ensure floor holes on a second floor walkway were guarded when employees were required to utilize the walkway.
Citation ID 02001
Citaton Type Other
Standard Cited 19040039 A02
Issuance Date 2021-04-01
Current Penalty 1504.0
Initial Penalty 2926.0
Final Order 2021-04-16
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.39(a)(2): The employer did not report the in-patient hospitalization of one or more employees to OSHA within twenty-four (24) hours: a) At 507 Amos Street, Crestview, Florida: On or about January 12, 2021 and at times prior; the employer failed to report an in-patient hospitalization within 24 hours of an employee who fell through a hole in a second floor walkway resulting in eight broken ribs and a broken collar bone. The employer reported the hospitalization on January 19, 2021.

U.S. Small Business Administration Profile

Status User ID Name of Firm Trade Name UEI Address
Active P3369533 PRECISION PLUMBING GROUP, INC - LYTGN85FXE73 2265 LAIRD RD, CRESTVIEW, FL, 32539-9363
Capabilities Statement Link -
Phone Number 850-603-8007
Fax Number -
E-mail Address precisionplumbinggroup@gmail.com
WWW Page -
E-Commerce Website -
Contact Person STEVEN MOSELEY
County Code (3 digit) 091
Congressional District 01
Metropolitan Statistical Area 2750
CAGE Code 0WQL8
Year Established 2020
Accepts Government Credit Card Yes
Legal Structure Subchapter S Corporation
Ownership and Self-Certifications Self-Certified Small Disadvantaged Business
Business Development Servicing Office NORTH FLORIDA DISTRICT OFFICE (SBA office code 0491)
Capabilities Narrative (none given)
Special Equipment/Materials (none given)
Business Type Percentages (none given)
Keywords (none given)
Quality Assurance Standards (none given)
Electronic Data Interchange capable -

SBA Federal Certifications

HUBZone Certified No
Women Owned Certified No
Women Owned Pending No
Economically Disadvantaged Women Owned Certified No
Economically Disadvantaged Women Owned Pending No
Veteran-Owned Small Business Certified No
Veteran-Owned Small Business Joint Venture No
Service-Disabled Veteran-Owned Small Business Certified No
Service-Disabled Veteran-Owned Small Business Joint Venture No

Bonding Levels

Description Construction Bonding Level (per contract)
Level (none given)
Description Construction Bonding Level (aggregate)
Level (none given)
Description Service Bonding Level (per contract)
Level (none given)
Description Service Bonding Level (aggregate)
Level (none given)

NAICS Codes with Size Determinations by NAICS

Primary Yes
Code 238220
NAICS Code's Description Plumbing, Heating, and Air?Conditioning Contractors
Buy Green Yes

Export Profile (Trade Mission Online)

Exporter Firm hasn't answered this question yet
Export Business Activities (none given)
Exporting to (none given)
Desired Export Business Relationships (none given)
Description of Export Objective(s) (none given)

Date of last update: 03 May 2025

Sources: Florida Department of State