Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-11-02
|
Emphasis |
N: FALL
|
Related Activity
Type |
Referral |
Activity Nr |
2098756 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2024-01-03 |
Current Penalty |
2846.0 |
Initial Penalty |
2846.0 |
Final Order |
2024-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying objects while using a nail gun. a) On or about 11/02/2023, at the jobsite located at 22813 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to eye injuries, in that, appropriate eye protection was not utilized while using a nail gun. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-01-03 |
Current Penalty |
2846.0 |
Initial Penalty |
2846.0 |
Final Order |
2024-02-13 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about 11/02/2023, at the jobsite located at 22813 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to fall hazards of approximately 9 feet 10 inches, in that, fall protection was not used while engaged in roofing activities while working on the roof. Front of structure. b) On or about 11/02/2023, at the jobsite located at 22813 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to fall hazards of approximately 18 feet 7 inches, in that, fall protection was not used while engaged in roofing activities while working on the roof. Rear of structure. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-01-03 |
Current Penalty |
2846.0 |
Initial Penalty |
2846.0 |
Final Order |
2024-02-13 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 11/02/2023, at the jobsite located at 22813 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to fall hazards of approximately 9 feet 10 inches, in that, the extension ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access. Front of structure. b) On or about 11/02/2023, at the jobsite located at 22813 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to fall hazards of approximately 18 feet 7 inches, in that, the extension ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access. Rear of structure. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2024-01-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-13 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i):Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support) a) On or about 11/02/2023, at the jobsite located at 22813 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to fall hazards of approximately 9 feet 10 inches, in that, the angle of the extension ladder in use to gain access to the roof was too shallow, 68.6 degrees. Front of structure. b) On or about 11/02/2023, at the jobsite located at 22813 Cherokee Rose Place, Land O' Lakes, Florida 34639 employees were exposed to fall hazards of approximately 18 feet 7 inches, in that, the angle of the extension ladder in use to gain access to the roof was too shallow, 71.4 degrees. Rear of structure. |
|
|