Search icon

PINAR STUCCO INC - Florida Company Profile

Company Details

Entity Name: PINAR STUCCO INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

PINAR STUCCO INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 18 Sep 2019 (6 years ago)
Date of dissolution: 25 Sep 2020 (5 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2020 (5 years ago)
Document Number: P19000073761
Address: 900 TEATRO CT, ORLANDO, FL, 32807, US
Mail Address: 900 TEATRO CT, ORLANDO, FL, 32807, US
ZIP code: 32807
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
FUENTES ERAZO MARIA E President 900 TEATRO CT, ORLANDO, FL, 32807
FUENTES ERAZO MARIA E Agent 900 TEATRO CT, ORLANDO, FL, 32807

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2020-09-25 - -

Documents

Name Date
Domestic Profit 2019-09-18

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344858238 0420600 2020-07-29 3800 DEER DR, SARASOTA, FL, 34240
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2020-07-29
Emphasis L: FALL, P: FALL
Case Closed 2024-03-18

Related Activity

Type Inspection
Activity Nr 1485810
Safety Yes
Type Inspection
Activity Nr 1485816
Safety Yes
Type Inspection
Activity Nr 1487519
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2020-09-21
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2021-02-16
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a. On or about 07/29/2020, at 3800 Deer Drive, Sarasota, FL 34240, employees were exposed to a fall hazard while working from a tubular welded frame scaffold 4 frames high and 7 frames wide, in that, 5 scaffold platforms were not fully planked as required allowing a 12 inch distance to the scaffold upright.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2020-09-21
Current Penalty 4048.0
Initial Penalty 4048.0
Final Order 2021-02-16
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about 07/29/2020, at 3800 Deer Drive, Sarasota, FL 34240, employees were exposed to a fall hazard while working from a tubular welded frame scaffold 4 frames high and 7 frames wide, in that, the scaffold was not provided with guardrails as required. The scaffold top frames (fourth frame) were missing the guardrails at the ends and at 6 other frames, the third frames were missing the guardrails at the ends and at 3 other frames and the second frames were missing the guardrails at the ends and at 3 other frames.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2020-09-21
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2021-02-16
Nr Instances 28
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a. On or about 07/29/2020, at 3800 Deer Drive, Sarasota, FL 34240, employees were exposed to a fall hazard while working from a tubular welded frame scaffold, 4 frames high and 7 frames wide, in that, cross bracing was not used at the side of the scaffold adjacent to the building.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2020-09-21
Abatement Due Date 2020-11-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-02-16
Nr Instances 1
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard: a. On or about 07/29/2020 at 3800 Deer Drive, Sarasota, FL 34240, the employer did not develop and implement a safety and health program to address the company policy on safety as well as the employer and employee responsibilities.

Date of last update: 01 May 2025