Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-03-13
|
Emphasis |
L: FORKLIFT
|
Related Activity
Type |
Inspection |
Activity Nr |
1656961 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2024-09-11 |
Abatement Due Date |
2024-10-29 |
Current Penalty |
4610.0 |
Initial Penalty |
4610.0 |
Final Order |
2024-10-08 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to crush-by hazards: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 13, 2024, the gantry crane was not periodically inspected at least once every 12 months, in that, the gantry crane used by employees to lift boats and boat components during assembling activities had signs of corrosion and/or damage. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100106 E06 II |
Issuance Date |
2024-09-11 |
Abatement Due Date |
2024-10-29 |
Current Penalty |
4610.0 |
Initial Penalty |
4610.0 |
Final Order |
2024-10-08 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 �F (37.8 �C), were dispensed into containers without the nozzle and container being electrically interconnected: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 13, 2024, the employer failed to ensure that category 3 flammable liquids such as the lamination resin drums in the lamination department were transferred between containers that cannot be electrically interconnected; exposing employees to a fire hazard. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100134 E01 |
Issuance Date |
2024-09-11 |
Abatement Due Date |
2024-10-29 |
Current Penalty |
7374.0 |
Initial Penalty |
7374.0 |
Final Order |
2024-10-08 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 13, 2024, the employer did not provide a medical evaluation to determine each employees' ability to use a respiratory before requiring use, in that, employees involved in grinding, cutting and sanding operations and grinding were provided and required to use tight-fitting facepiece respirators. The BLACKTIP BOATWORKS LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 1656961, citation number 1, item number 3b and was affirmed as a final order on August 8, 2023, with respect to a workplace located at 7301 74th Street North Pinellas Park, Florida 33781. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19100134 F01 |
Issuance Date |
2024-09-11 |
Abatement Due Date |
2024-10-29 |
Current Penalty |
7374.0 |
Initial Penalty |
7374.0 |
Final Order |
2024-10-08 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a: At 7301 74th Street North Pinellas Park, Florida; On or about March 13, 2024, the employer did not provide a fit test to employees involved in the grinding, cutting and sanding operations, provided and required to use tight-fitting facepiece respirators. The BLACKTIP BOATWORKS LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(f)(1), which was contained in OSHA inspection number 1656961, citation number 1, item number 3c and was affirmed as a final order on August 8, 2023, with respect to a workplace located at 7301 74th Street North Pinellas Park, Florida 33781. |
|
Citation ID |
02003 |
Citaton Type |
Repeat |
Standard Cited |
19101200 H01 |
Issuance Date |
2024-09-11 |
Abatement Due Date |
2024-10-29 |
Current Penalty |
9219.0 |
Initial Penalty |
9219.0 |
Final Order |
2024-10-08 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 13, 2024, the employer did not provide information and training to employees handling chemical products such as Norox MEKP-9, ArJay, Ultra UHD2399, XM 1808 45/45 cloth and 3M Hitrack 71. The BLACKTIP BOATWORKS LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(h)(1), which was contained in OSHA inspection number 1656961, citation number 1, item number 9c and was affirmed as a final order on August 8, 2023, with respect to a workplace located at 7301 74th Street North Pinellas Park, Florida 33781. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2024-09-11 |
Abatement Due Date |
2024-10-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-10-08 |
Nr Instances |
1 |
Nr Exposed |
9 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 13, 2024, the employer did not provide the Appendix D information to employees provided with disposable filtering facepiece respirators for voluntary use while performing lamination activities. |
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2023-05-25
|
Emphasis |
L: FORKLIFT, L: HINOISE
|
Related Activity
Type |
Complaint |
Activity Nr |
2007706 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2023-07-11 |
Current Penalty |
4465.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, employees were exposed to a 9-foot fall hazard while accessing the storage area above the office, in that, the landing of the storage area stairway had a vertical opening on the landing left side. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100037 A03 |
Issuance Date |
2023-07-11 |
Current Penalty |
4465.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the emergency exit and exit access were obstructed by a storage rack, a wood pallet with a propane cylinder gas tank and an acetone metal drum, restricting employees movement thru the exit access and preventing prompt access to the exit. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
3572.0 |
Initial Penalty |
3572.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Inspection NR |
1736375 |
FTA Issuance Date |
2024-09-11 |
FTA Current Penalty |
53096.0 |
FTA Final Order Date |
2024-10-08 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the employer did not develop and implement a written worksite specific respiratory protection program for employees provided and required to use tight-fitting facepiece respirators. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the employer did not provide a medical evaluation to determine each employees' ability to use a respiratory before requiring use, in that, employees involved in the gel coat application, cutting and grinding were provided and required to use tight-fitting facepiece respirators. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19100134 F01 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the employer did not provide a fit test to employees involved in the gel coat application, cutting and grinding were provided and required to use tight-fitting facepiece respirators. |
|
Citation ID |
01003D |
Citaton Type |
Serious |
Standard Cited |
19100134 H03 II A |
Issuance Date |
2023-07-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(h)(3)(ii)(A): Respirator inspections did not include a check of respirator function, tightness of connections, and the condition of the various parts including, but not limited to, the facepiece, head straps, valves, connecting tube, and cartridges, canisters or filters: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the employer did not ensure that respirators are inspected before use, in that, at the gel coat application area a 3M Half Facepiece Reusable Respirator with OV and a P95 the headband retainer was observed with the headband straps snaps deteriorated and unable to fasten to the elastomeric portion of the mask. |
|
Citation ID |
01003E |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the employer did not develop and implement a written work-site specific respiratory protection program for employees provided and required to use tight-fitting facepiece respirators. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100178 L06 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
4465.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16,2023, the employer failed to certify that powered industrial truck operators had been trained and evaluated. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
4465.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the Yale - LP powered industrial truck was not taken out of service while the master brake was in need of repair, exposing employees to struck-by hazards. b: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the Yale - LP powered industrial truck was not taken out of service while the horn was not operational, exposing employees to struck-by hazards. c: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the Yale - LP powered industrial truck was not taken out of service while the seatbelt was not functional, exposing employees to entrapment between the truck and the ground in the event of a tip-over. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100179 B05 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
4465.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the gantry crane rated load was not marked on each side of the crane, exposing employees to crush-by hazards. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
4465.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Inspection NR |
1736375 |
FTA Issuance Date |
2024-09-11 |
FTA Current Penalty |
103716.0 |
FTA Final Order Date |
2024-10-08 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, a compressed air line in the cutting and grinding area used for cleaning dust off surfaces, had a pressure per square inch of 100. |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 I |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
4465.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, in the office area, switch and outlet boxes were not covered, exposing employees to electric shock and fire hazards. |
|
Citation ID |
01009A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
4465.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Inspection NR |
1736375 |
FTA Issuance Date |
2024-09-11 |
FTA Current Penalty |
138288.0 |
FTA Final Order Date |
2024-10-08 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16,2023, the employer did not develop, implement, and/or maintain at the workplace a written hazard communication program for employees handling chemical products containing styrene, fibrous glass, acetone, benzene, toluene and methyl ethyl ketone. |
|
Citation ID |
01009B |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Inspection NR |
1736375 |
FTA Issuance Date |
2024-09-11 |
FTA Current Penalty |
0.0 |
FTA Final Order Date |
2024-10-08 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the employer did maintain safety data sheets for employees handling chemical products such as Norox MEKP-9, ArJay, Ultra UHD2399, XM 1808 45/45 cloth and 3M Hitrack 71. |
|
Citation ID |
01009C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2023-07-11 |
Abatement Due Date |
2023-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-08 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a: At 7301 74th Street North Pinellas Park, Florida; On or about March 16, 2023, the employer did not provide information and training to employees handling chemical products such as Norox MEKP-9, ArJay, Ultra UHD2399, XM 1808 45/45 cloth and 3M Hitrack 71. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2023-11-17 |
Abatement Due Date |
2024-01-08 |
Current Penalty |
501.0 |
Initial Penalty |
501.0 |
Final Order |
2023-12-14 |
Nr Instances |
1 |
Nr Exposed |
11 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) On or bout November 17, 2023, the employer failed to submit the certification of corrective action, including the date and method of abatement, for each citation issued on July 11, 2023. |
|
|