Search icon

GOMEZ CARPENTER SERVICES, INC. - Florida Company Profile

Company Details

Entity Name: GOMEZ CARPENTER SERVICES, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

GOMEZ CARPENTER SERVICES, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 15 May 2019 (6 years ago)
Date of dissolution: 04 Dec 2024 (5 months ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 04 Dec 2024 (5 months ago)
Document Number: P19000042972
FEI/EIN Number 37-1945226

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5217 WILLOW BREEZE WAY, PALMETTO, FL, 34221, US
Mail Address: 5217 WILLOW BREEZE WAY, PALMETTO, FL, 34221, US
ZIP code: 34221
County: Manatee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
GARAY JIMENEZ LUCIA President 5217 WILLOW BREEZE WAY, PALMETTO, FL, 34221
GOMEZ OSCAR R Vice President 5217 WILLOW BREEZE WAY, PALMETTO, FL, 34221
GARAY JIMENEZ LUCIA Agent 5217 WILLOW BREEZE WAY, PALMETTO, FL, 34221

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2024-12-04 - -

Documents

Name Date
VOLUNTARY DISSOLUTION 2024-12-04
ANNUAL REPORT 2024-03-22
ANNUAL REPORT 2023-04-29
ANNUAL REPORT 2022-04-05
ANNUAL REPORT 2021-03-04
ANNUAL REPORT 2020-02-18
Domestic Profit 2019-05-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346517386 0420600 2023-02-21 9605 GULF DRIVE, ANNA MARIA, FL, 34216
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-02-21
Emphasis L: FALL, P: FALL
Case Closed 2024-06-07

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-05-05
Abatement Due Date 2023-05-17
Current Penalty 2344.0
Initial Penalty 4688.0
Final Order 2023-06-07
Nr Instances 2
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about and at time prior to February 21, 2023, at the job-site located at 9605 Gulf Drive Anna Maria, Florida. Employees were exposed to fall hazards of approximately 9 feet 7 inches while framing a residential structure, in that, fall protection was not used. b) On or about and at time prior to February 21, 2023, at the job-site located at 9605 Gulf Drive Anna Maria, Florida. Employees were exposed to fall hazards of approximately 20 feet 5 inches while framing a residential structure, in that, fall protection was not used.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B14
Issuance Date 2023-05-05
Abatement Due Date 2023-05-17
Current Penalty 2344.0
Initial Penalty 4688.0
Final Order 2023-06-07
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a) On or about February 21, 2023, at the job-site located at 9605 Gulf Drive Anna Maria, Florida. Employees who were doing frame work on the second floor were exposed to fall hazards of approximately 9 feet 7 inches due to wall and window openings which were not guarded.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260503 A02
Issuance Date 2023-05-05
Abatement Due Date 2023-06-01
Current Penalty 2344.0
Initial Penalty 4688.0
Final Order 2023-06-07
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii) a) On or about February 21, 2023, at the job-site located at 9605 Gulf Drive Anna Maria, Florida. Employees were exposed to falls hazards, in that in that fall protection training including recognition of fall hazards and the procedures to minimize/eliminate exposure.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2023-05-05
Abatement Due Date 2023-06-01
Current Penalty 2344.0
Initial Penalty 4688.0
Final Order 2023-06-07
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about February 21, 2023, at the job-site located at 9605 Gulf Drive Anna Maria, Florida. Employees involved in framing activities were exposed to falls of approximately 9 feet 7 inches, in that, the extension ladder was not extended 3 feet above the landing surface.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2023-05-05
Abatement Due Date 2023-06-01
Current Penalty 2344.0
Initial Penalty 4688.0
Final Order 2023-06-07
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about February 21, 2023, at the job-site located at 9605 Gulf Drive Anna Maria, Florida. Employees were exposed to falls of approximately 10 feet 10 inches while using a step ladder in the leaning position to access the third floor.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2023-05-05
Abatement Due Date 2023-05-17
Current Penalty 2344.0
Initial Penalty 4688.0
Final Order 2023-06-07
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder. a) On or about February 21, 2023, at the job-site located at 9605 Gulf Drive Anna Maria, Florida. The 20-ft. Werner aluminum extension ladder used to access the second level of the structure, was use at an angle that the horizontal distance from the top support to the foot of the ladder (approximately 9-feet and 6 inches) was more than one quarter of the working length of the ladder (4-feet approximately), exposing employees to a fall hazard.