Search icon

FLORIDA STATE ROOFING CORP

Company Details

Entity Name: FLORIDA STATE ROOFING CORP
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Active
Date Filed: 11 Apr 2019 (6 years ago)
Document Number: P19000032783
FEI/EIN Number 83-4524611
Address: 1626 ROBERTS LANDING RD, WINDERMERE, FL 34786
Mail Address: 1626 ROBERTS LANDING RD, WINDERMERE, FL 34786
ZIP code: 34786
County: Orange
Place of Formation: FLORIDA

Agent

Name Role Address
BARROS, DENNYS S Agent 1626 ROBERTS LANDING RD, WINDERMERE, FL 34786

President

Name Role Address
BARROS, DENNYS S President 1626 ROBERTS LANDING RD, WINDERMERE, FL 34786

Vice President

Name Role Address
Soares, Marcella Padula Vice President 1626 roberts landing rd, windermere, FL 34786

Documents

Name Date
ANNUAL REPORT 2024-02-22
ANNUAL REPORT 2023-03-31
ANNUAL REPORT 2022-04-27
ANNUAL REPORT 2021-04-30
ANNUAL REPORT 2020-06-29
Domestic Profit 2019-04-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347479024 0419730 2024-05-14 1163 CARMEL CIR., CASSELBERRY, FL, 32707
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-05-14
Emphasis N: FALL, P: FALL
Case Closed 2024-06-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-05-17
Current Penalty 2903.4
Initial Penalty 4839.0
Final Order 2024-05-31
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about May 14, 2024, at the clubhouse: employees were exposed to 9 foot 7 inch fall hazards while installing terracotta roof tiles on a 6/12 pitched roof, in that a fall protection system was not used.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2024-05-17
Abatement Due Date 2024-06-13
Current Penalty 232.8
Initial Penalty 388.0
Final Order 2024-05-31
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. On or about May 14, 2024, at the clubhouse: the employer did not prepare and maintain a written fall protection training program certification for employees exposed to fall hazards of 9 feet 7 inches while working on the roof.