Search icon

BLUEWATER CONSTRUCTION SOLUTIONS OF SEBASTIAN INC. - Florida Company Profile

Company Details

Entity Name: BLUEWATER CONSTRUCTION SOLUTIONS OF SEBASTIAN INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

BLUEWATER CONSTRUCTION SOLUTIONS OF SEBASTIAN INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 17 Dec 2018 (6 years ago)
Date of dissolution: 25 Sep 2020 (5 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2020 (5 years ago)
Document Number: P18000101621
FEI/EIN Number 83-2876764

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 4548 CANARD RD, MELBOURNE, FL, 32934, US
Mail Address: 4548 CANARD RD, MELBOURNE, FL, 32934, US
ZIP code: 32934
County: Brevard
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
GELLER NAKIA I Vice President 4548 CANARD, MELBOURNE, FL, 32934
GELLER CALEB P President 4548 CANARD RD, MELBOURNE, FL, 32934
PELLETIER FRANCOIS Secretary 4548 CANARD RD, MELBOURNE, FL, 32934
GELLER NAKIA I Agent 4548 CANARD RD., MELBOURNE, FL, 32934

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2020-09-25 - -
AMENDMENT 2019-01-24 - -

Documents

Name Date
ANNUAL REPORT 2019-02-07
Amendment 2019-01-24
Domestic Profit 2018-12-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344299011 0418800 2019-09-11 5610 SE GROUPER AVENUE, STUART, FL, 34997
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-09-11
Emphasis L: FALL, P: FALL
Case Closed 2021-09-23

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2019-11-05
Current Penalty 6630.0
Initial Penalty 6630.0
Final Order 2019-12-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about September 11, 2019, at the northeast corner and south roof edges of a commercial building under construction located at 5610 SE Grouper Avenue in Stuart, Florida, employees were exposed to a fall hazard of approximately 14 feet - 6 inches when performing carpentry work on the roof of the structure with a 3 on 12 pitch while not being protected from falling to the lower level.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2019-11-05
Abatement Due Date 2019-11-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about September 11, 2019, on site of a commercial building under construction located at 5610 SE Grouper Avenue in Stuart, Florida, employees were exposed to a fall hazard when performing carpentry work on the roof of the structure prior to being provided with training that would enable them to recognize the hazards associated with falls.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2019-11-05
Current Penalty 5304.0
Initial Penalty 5304.0
Final Order 2019-12-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about September 11, 2019, on site of a commercial building under construction located at 5610 SE Grouper Avenue in Stuart, Florida, employees were exposed to a fall hazard of approximately 10 feet when gaining access to and from a roof while using a ladder that was not extended at least 3 feet past the roof edge and was not secured to prevent accidental displacement.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2019-11-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: On or about September 11, 2019, on site of a commercial building under construction located at 5610 SE Grouper Avenue in Stuart, Florida, employees were exposed to a fall hazard when using an extension ladder to gain access to and from the lower roof of a structure prior to being provided with training that would enable them to recognize the hazards associated with ladders.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B22
Issuance Date 2019-11-05
Current Penalty 5304.0
Initial Penalty 5304.0
Final Order 2019-12-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause them to lose balance and fall: On or about September 11, 2019, on site of a commercial building under construction located at 5610 SE Grouper Avenue in Stuart, Florida, employees were exposed to a fall hazard of approximately 10 feet from an extension ladder when carrying objects including but not limited to a saw-zall, pneumatic nail gun and/or a box of nails which could cause them to lose balance and fall.