Search icon

AARON ROOFING CONSTRUCTION AND SIDING INC - Florida Company Profile

Company Details

Entity Name: AARON ROOFING CONSTRUCTION AND SIDING INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

AARON ROOFING CONSTRUCTION AND SIDING INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 11 Dec 2018 (6 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 10 Nov 2020 (4 years ago)
Document Number: P18000100664
FEI/EIN Number 83-2833920

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 4083 SUNBEAM RD, JACKSONVILLE, FL, 32257, US
Mail Address: 4083 SUNBEAM RD, JACKSONVILLE, FL, 32257, US
ZIP code: 32257
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
DUBON OLIVA MAYNOR President 4083 SUNBEAM RD, JACKSONVILLE, FL, 32257
DUBON OLIVA MAYNOR Agent 4083 SUNBEAM RD, JACKSONVILLE, FL, 32257

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2022-04-27 4083 SUNBEAM RD, APT 409, JACKSONVILLE, FL 32257 -
CHANGE OF MAILING ADDRESS 2022-04-27 4083 SUNBEAM RD, APT 409, JACKSONVILLE, FL 32257 -
REGISTERED AGENT ADDRESS CHANGED 2022-04-27 4083 SUNBEAM RD, APT 409, JACKSONVILLE, FL 32257 -
REINSTATEMENT 2020-11-10 - -
REGISTERED AGENT NAME CHANGED 2020-11-10 DUBON OLIVA, MAYNOR -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -

Documents

Name Date
ANNUAL REPORT 2024-01-30
ANNUAL REPORT 2023-02-13
ANNUAL REPORT 2022-04-27
ANNUAL REPORT 2021-04-28
REINSTATEMENT 2020-11-10
Domestic Profit 2018-12-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346439458 0419700 2023-01-17 3840 BEACH BLVD, JACKSONVILLE, FL, 32207
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-01-17
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2023-01-27
Current Penalty 5156.0
Initial Penalty 5156.0
Final Order 2023-03-16
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems or a combination of warning line system and safety monitoring system: a. On or about January 17, 2023, low slope roof, three employees installing a metal roof were not protected from the hazard of falling 8 feet 11 inches by the use of guardrails, safety nets, personal fall protection, or any other form of alternative fall protection.
345409817 0419700 2021-07-09 13700 SUTTUN PARK DRIVE N., JACKSONVILLE, FL, 32224
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2021-07-09
Emphasis L: FALL

Related Activity

Type Complaint
Activity Nr 1784353
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2021-09-13
Current Penalty 5149.0
Initial Penalty 5149.0
Final Order 2021-10-07
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. At Building 14, on a multi-family residential apartment rooftop located at 13700 Sutton Park Drive N., Jacksonville FL: On or about July 9, 2021, the employer exposed employees to being hit or struck-by flying debris in that, an employee was using a Dewalt circular saw without safety glasses.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2021-09-13
Current Penalty 12015.0
Initial Penalty 12015.0
Final Order 2021-10-07
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At Building 14, on a multi-family residential apartment rooftop located at 13700 Sutton Park Drive N., Jacksonville FL: On or about July 9, 2021, the employer exposed employees to a 28-foot fall hazard, in that fall protection was not utilized by any employees while conducting re-roofing operations. The Aaron Roofing and Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1479371, citation number 1, item number 1 and was affirmed as a final order on November 18, 2020, with respect to a workplace located at 2044 N. Cranbrook Avenue, St. Augustine, Florida 32092.
344793716 0419700 2020-06-17 2044 N. CRANBROOK AVE., SAINT AUGUSTINE, FL, 32092
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2020-06-17
Emphasis L: FALL, P: FALL
Case Closed 2022-10-06

Related Activity

Type Inspection
Activity Nr 1479386
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2020-10-21
Current Penalty 3932.0
Initial Penalty 3932.0
Final Order 2020-11-19
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about June 17, 2020 on the slopes of the 6:12 roof, seven employees performing re-roofing work were exposed to a nine feet fall hazard in that they were not protected by a fall protection system.
Citation ID 02001A
Citaton Type Other
Standard Cited 19261053 B01
Issuance Date 2020-10-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-11-19
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about June 17, 2020, the roof access ladder used by seven roofing employees was not extended 36 inches above the eave.
Citation ID 02001B
Citaton Type Other
Standard Cited 19261053 B05 I
Issuance Date 2020-10-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-11-19
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a. On or about June 17, 2020, the roof access ladder used by seven roofing employees was set at a 60-degree angle of repose, 14 degrees shallower than required by standard.

Date of last update: 02 Apr 2025

Sources: Florida Department of State