Search icon

J J SORTO CONSTRUCTION INC - Florida Company Profile

Company Details

Entity Name: J J SORTO CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

J J SORTO CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 29 Oct 2018 (6 years ago)
Date of dissolution: 25 Sep 2020 (4 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2020 (4 years ago)
Document Number: P18000090143
FEI/EIN Number 83-2412617

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 605 NORTH 8TH STREET, FORT PIERCE, FL, 34950, US
Mail Address: 605 NORTH 8TH STREET, FORT PIERCE, FL, 34950, US
ZIP code: 34950
County: St. Lucie
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
SORTO JOSE S President 605 NORTH 8TH STREET, FORT PIERCE, FL, 34950
SORTO JOSE S Agent 605 NORTH 8TH STREET, FORT PIERCE, FL, 34950

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2020-09-25 - -
REGISTERED AGENT ADDRESS CHANGED 2019-10-30 605 NORTH 8TH STREET, FORT PIERCE, FL 34950 -
CHANGE OF PRINCIPAL ADDRESS 2019-10-30 605 NORTH 8TH STREET, FORT PIERCE, FL 34950 -
CHANGE OF MAILING ADDRESS 2019-10-30 605 NORTH 8TH STREET, FORT PIERCE, FL 34950 -
REGISTERED AGENT NAME CHANGED 2019-10-30 SORTO, JOSE S -
REINSTATEMENT 2019-10-30 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
AMENDMENT 2018-12-26 - -
AMENDMENT 2018-12-17 - -

Documents

Name Date
REINSTATEMENT 2019-10-30
Amendment 2018-12-26
Amendment 2018-12-17
Domestic Profit 2018-10-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344641253 0418800 2020-02-20 4821 SE ARDSLEY DRIVE, STUART, FL, 34997
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2020-02-20
Emphasis L: FALL, P: FALL
Case Closed 2022-04-05

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2020-04-24
Current Penalty 2313.0
Initial Penalty 2313.0
Final Order 2020-05-28
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On or about February 20, 2020, on the southeast roof corner of a residential structure under construction located at 4821 SE Ardsley Drive in Stuart, Florida, an employee was exposed to a struck-by eye injury when operating a pneumatic nail gun to secure plywood sheathing while not wearing eye protection equipment. b) On or about February 20, 2020, on the southeast roof corner of a residential structure under construction located at 4821 SE Ardsley Drive in Stuart, Florida, an employee was exposed to a struck-by eye injury when operating a circular saw to cut plywood sheathing while not wearing eye protection equipment.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2020-04-24
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2020-05-28
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): On or about February 20, 2020, on the southeast roof corner of a residential structure under construction located at 4821 SE Ardsley Drive in Stuart, Florida, employees exposed to a fall hazard of approximately 12-feet when performing plywood sheathing installation work on the roof of a residential building with a 6 on 12-inch pitch while not being protected from falling to the lower level.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2020-04-24
Abatement Due Date 2020-05-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-05-28
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about February 20, 2020, on the southeast roof corner of a residential structure under construction located at 4821 SE Ardsley Drive in Stuart, Florida, an employees was exposed to a fall hazard of approximately 12-feet when performing plywood sheathing installation work on the roof of a residential building prior to being provided with a training program that would enable him to recognize the hazards associated with falls.