346904196
|
0420600
|
2023-08-03
|
1106 SE 12TH CT, CAPE CORAL, FL, 33990
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-08-03
|
Emphasis |
N: FALL
|
Case Closed |
2024-01-18
|
Related Activity
Type |
Complaint |
Activity Nr |
2061013 |
Safety |
Yes |
|
|
343789731
|
0419700
|
2019-02-15
|
603 BREAKFAST POINT BLVD, PANAMA CITY BEACH, FL, 32407
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-02-15
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-03-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-03-13 |
Current Penalty |
4569.2 |
Initial Penalty |
7956.0 |
Final Order |
2019-04-05 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about February 15, 2019, on the 6:12 pitch roof, employees removing old roofing shingles were exposed to a 10 feet fall hazard from the eaves in that they were not protected by a fall protection system. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2019-03-13 |
Current Penalty |
3712.8 |
Initial Penalty |
5304.0 |
Final Order |
2019-04-05 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about February 15, 2019, at the right eave of the roof, the roof access ladder was not extended at least 3 feet above the roof edge, exposing employees to a 9 feet and 10 inches fall hazard. |
|
|
343785002
|
0419700
|
2019-02-14
|
5230 W. HWY 98 GULF COAST STATE COLLEGE WELLNESS BUILDING/FITNESS CENTER, PANAMA CITY, FL, 32405
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-02-15
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-08-19
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2019-03-12 |
Current Penalty |
5589.2 |
Initial Penalty |
9282.0 |
Final Order |
2019-04-05 |
Nr Instances |
1 |
Nr Exposed |
23 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a. On or about February 14, 2019, on the 1:12 pitch gymnasium roof, a warning line was not erected with the use of a monitoring system to alert roofing employees of the roof edge, exposing employees to a 35 feet fall hazard, and no other fall protection system was in use. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 III |
Issuance Date |
2019-03-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-05 |
Nr Instances |
1 |
Nr Exposed |
23 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used. a. On or about February 14, 2019, the employer had not trained designated monitors and employees covered by the monitor system on the requirements for a warning line system. |
|
|