Entity Name: | D N S. CONTRACTORS INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Profit Corporation
D N S. CONTRACTORS INC. is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 11 Jul 2018 (7 years ago) |
Date of dissolution: | 27 Sep 2019 (5 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 27 Sep 2019 (5 years ago) |
Document Number: | P18000060380 |
Address: | 103 W JACKSON. STREET, KISSIMMEE, FL 34741 |
Mail Address: | 103 W JACKSON. STREET, KISSIMMEE, FL 34741 |
ZIP code: | 34741 |
County: | Osceola |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SANTOS, JOSE A | President | 103, W JACKSON. STREET KISSIMMEE, FL 34741 |
SANTOS, JOSE A | Director | 103, W JACKSON. STREET KISSIMMEE, FL 34741 |
LEGALCORP SOLUTIONS, LLC | Agent | - |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2019-09-27 | - | - |
Name | Date |
---|---|
Domestic Profit | 2018-07-11 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340703495 | 0420600 | 2015-06-09 | 4264 ADLAAR DR, SARASOTA, FL, 34232 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2015-07-13 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-08-11 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. At the site, on or about, 06/09/2015 an employee was exposed to a 9 foot 9 inch fall hazard, in that, no fall protection was used while taking measurements from the top of the wall. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2015-07-13 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-08-11 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. At the site, on or about 06/09/2015 an employee was exposed to a fall hazard, in that the top step of a step ladder was used as a means of access and egress from a 9 foot 9 inch wall. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2015-04-15 |
Emphasis | P: FALL, L: FALL |
Case Closed | 2018-11-28 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B02 |
Issuance Date | 2015-05-08 |
Abatement Due Date | 2015-05-20 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-06-09 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: On or about 15 April, 2015, at the above addressed job site, four employees were working from a temporary scaffold up to approximately 6 feet and 10 inches high without the platform being at least 18 inches wide, exposing the employees to a fall hazard. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 F03 |
Issuance Date | 2015-05-08 |
Abatement Due Date | 2015-05-20 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-06-09 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about 15 April, 2015, at the above addressed job site, four employees were working from a temporary scaffold up to approximately 6 feet and 10 inches high without the scaffold being inspected by a competent person, exposing the employee to a fall hazard. |
Date of last update: 17 Feb 2025
Sources: Florida Department of State