Search icon

DOMINGOS 54 CONSTRUCTION INC - Florida Company Profile

Company Details

Entity Name: DOMINGOS 54 CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

DOMINGOS 54 CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 11 May 2018 (7 years ago)
Date of dissolution: 22 Sep 2023 (2 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2023 (2 years ago)
Document Number: P18000043932
FEI/EIN Number 83-0550364

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 16057 Tampa Palms, #221, Tampa, FL, 33543, US
Mail Address: 16057 Tampa Palms, #221, Tampa, FL, 33543, US
ZIP code: 33543
County: Pasco
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
PITA MANUEL President 2901 SW 41ST ST, TAMPA, FL, 34474
PITA MANUEL Agent 2901 SW 41ST ST, OCALA, FL, 34474

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G18000059451 DOMINGO GENERAL REMODELING EXPIRED 2018-05-16 2023-12-31 - 15350 AMBERLY DR APT 201, TAMPA, FL, 33647

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2023-09-22 - -
CHANGE OF PRINCIPAL ADDRESS 2022-03-17 16057 Tampa Palms, #221, Tampa, FL 33543 -
CHANGE OF MAILING ADDRESS 2022-03-17 16057 Tampa Palms, #221, Tampa, FL 33543 -
REGISTERED AGENT ADDRESS CHANGED 2020-04-23 2901 SW 41ST ST, OCALA, FL 34474 -

Documents

Name Date
ANNUAL REPORT 2022-03-17
ANNUAL REPORT 2021-04-12
ANNUAL REPORT 2020-04-23
ANNUAL REPORT 2019-04-29
Domestic Profit 2018-05-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347524357 0420600 2024-06-04 10813 APPLEWOOD RANGE WAY, TAMPA, FL, 33647
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2024-06-04
Case Closed 2024-06-04

Related Activity

Type Inspection
Activity Nr 1467585
Safety Yes
345584221 0420600 2021-10-18 5416 SPANISH MOSS CV, BRADENTON, FL, 34203
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-10-18
Emphasis L: FALL, P: FALL
Case Closed 2024-01-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2022-04-14
Abatement Due Date 2022-05-03
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2022-06-14
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a) At the site, on or about 10/18/2021, employees did not use eye protective equipment when operating nail guns, exposing them to potential eye injury.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B04 II
Issuance Date 2022-04-14
Abatement Due Date 2022-05-03
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2022-06-14
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(ii):Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: a) At the site, on or about 10/18/2021 and on days prior, employees working on the second floor of the site were not protected from tripping in or stepping into or through an approximately 2 ft wide hole 9 feet 4 inches above the lower level by covers, exposing them to trip and fall hazards.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-04-14
Abatement Due Date 2022-05-03
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2022-06-14
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At the site, on or about 10/18/2021, portable ladders used by employees did not have their side rails extend 3 ft above the upper landing surface being accessed, exposing employees using them to fall hazards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261060 A01 III
Issuance Date 2022-04-14
Abatement Due Date 2022-05-03
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2022-06-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1)(iii):The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways: a) At the site, on or about 10/18/2021 and on dates prior, the employer did not ensure that employees using ladders had been trained in their proper construction, use, placement, and care in handling, exposing employees using them to fall hazards due to misuse of ladders.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2022-04-14
Abatement Due Date 2022-05-03
Current Penalty 29005.0
Initial Penalty 29005.0
Final Order 2022-06-14
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) The employer fails to ensure effective protection against falls as required by the standard, as demonstrated on or about October 18, 2021, at a new home construction site located at 5416 Spanish Moss CV, Bradenton, FL, 34203, when employees were performing framing work on a roof, without fall protection, are exposed to a fall hazard of 25 feet 3 and 3/16th inches to ground level. To abate this violation, the employer must ensure that all employees are provided with and utilize fall protection or install a guardrail or safety net system when an employee works 6 feet or more above lower levels. Pursuant to 29 CFR 1903.19, the employer must submit documents describing the measures it is taking to ensure compliance, including an explanation of how these steps protect its employees from fall hazards.
345530208 0420600 2021-09-14 607 W EUCLID AVE, TAMPA, FL, 33602
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-09-14
Emphasis L: FALL, P: FALL
Case Closed 2024-01-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2022-03-10
Abatement Due Date 2022-03-29
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2022-04-08
Nr Instances 3
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) At 607 W Euclid Ave, Tampa FL: On or about September 14, 2021, the employer did not provide frequent and regular inspection of the job site.
345384218 0420600 2021-06-24 2504 W. PARKLAND BLVD, TAMPA, FL, 33609
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2021-06-24
Emphasis L: FALL
Case Closed 2024-01-09

Related Activity

Type Complaint
Activity Nr 1780648
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260503 A01
Issuance Date 2021-12-13
Abatement Due Date 2022-01-10
Current Penalty 12015.0
Initial Penalty 12015.0
Final Order 2022-01-19
Nr Instances 3
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) At the jobsite, employees were installing wood sheathing and framing a 4:12 sloped roof area of a residence. Employer did not provided fall protection training to the employees, exposing the employees to a fall hazard, on or about June 24, 2021. The Domingos 54 Construction Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1), which was contained in OSHA inspection number 1467585, citation number 1, item number 1 and was affirmed as a final order on 9/21/2020, with respect to a workplace located at 10813 Applewood Range Way, Tampa, FL.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2021-12-13
Abatement Due Date 2022-01-10
Current Penalty 60074.0
Initial Penalty 60074.0
Final Order 2022-01-19
Nr Instances 3
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Employees installing framing lumber at elevations of 6 feet or more above the ground are not being protected from fall hazards by a fall protection system: The employer fails to assure effective protection against falls as required by the standard, as demonstrated on June 24, 2021, when 3 employees installing framing lumber on a 4:12 pitch roof of a house located at 2504 W Parkland Blvd in Tampa, Florida, were exposed to an over 23 feet fall hazard to the ground, in that, fall protection equipment was not installed or utilized.
345304448 0420600 2021-05-12 9251 -9255 ROYAL RIVER CIR, PARRISH, FL, 34219
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-05-13
Emphasis L: FALL, P: FALL
Case Closed 2024-01-09

Related Activity

Type Inspection
Activity Nr 1530447
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Willful
Standard Cited 19260501 B11
Issuance Date 2021-08-31
Abatement Due Date 2021-09-27
Current Penalty 60074.0
Initial Penalty 60074.0
Final Order 2021-10-01
Nr Instances 3
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11):Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: At the jobsite, employees were exposed to a fall hazard of approximately 18 feet 7/8 inches, while conducting framing/decking work on an 5:12 pitch roof without fall protection, on or about May 12, 2021.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260102 A01
Issuance Date 2021-08-31
Abatement Due Date 2021-09-27
Current Penalty 25747.0
Initial Penalty 25747.0
Final Order 2021-10-01
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical agents: At the jobsite, Employees were using a pneumatic nail gun to frame the roofing area and install wood sheeting without using eye protection, exposing employees to a struck-by hazard, on or about May 12, 2021. The Domingos 54 Construction Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.102(a)(1), which was contained in OSHA inspection number 1416242, citation number 2, item number 1 and was affirmed as a final order on 10/21/2019, with respect to a workplace located at 9756-9760 Pembrooke Pines, Ruskin, FL, The Domingos 54 Construction Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.102(a)(1), which was contained in OSHA inspection number 1378608, citation number 1, item number 1 and was affirmed as a final order on 8/14/2019, with respect to a workplace located at 7309 Paradiso Dr, Apollo Beach, FL. The Domingos 54 Construction Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.102(a)(1), which was contained in OSHA inspection number 1388590, citation number 1, item number 1 and was affirmed as a final order on 6/24/2019, with respect to a workplace located at 13319 Saw Palm Creek Trail, Lakewood Ranch, FL.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260503 A01
Issuance Date 2021-08-31
Abatement Due Date 2021-09-27
Current Penalty 12015.0
Initial Penalty 12015.0
Final Order 2021-10-01
Nr Instances 3
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee who might be exposed to fall hazards: a) At the jobsite 9251 Royal River Cir, Parrish, FL employees were installing wood sheeting and framing an 5/12 sloped roof area of a residence. Employer did not provided fall protection training to the employees, exposing the employees to a fall hazard, on or about May 12, 2021. b) At the jobsite, 9255 Royal River Cir, Parrish, FL employees were installing wood sheeting and framing an 5/12 sloped roof area of a residence. Employer did not provided fall protection training to the employees, exposing the employees to a fall hazard, on or about May 12, 2021. The Domingos 54 Construction Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1), which was contained in OSHA inspection number 1467585, citation number 1, item number 1 and was affirmed as a final order on 9/21/2020, with respect to a workplace located at 10813 Applewood Range Way, Tampa, FL.
Citation ID 02003
Citaton Type Repeat
Standard Cited 19261053 B01
Issuance Date 2021-08-31
Abatement Due Date 2021-09-27
Current Penalty 21457.0
Initial Penalty 21457.0
Final Order 2021-10-01
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS) On the job site, a portable ladder was being utilized in which did not extend 3 feet above the roof's edge, exposing employees to a fall hazard, on or about May 12, 2021. The Domingos 54 Construction Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1), which was contained in OSHA inspection number 1416242, citation number 1, item number 2 and was affirmed as a final order on 10/21/2019, with respect to a workplace located at 9756-9760 Pembrook Pines, Ruskin, FL 33570. The Domingos 54 Construction Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1), which was contained in OSHA inspection number 1388590, citation number 1 , item number 3 and was affirmed as a final order on 6/24/2019, with respect to a workplace located at 13319 Saw Palm Creek Trail, Lakewood Ranch, FL.
Citation ID 02004
Citaton Type Repeat
Standard Cited 19261060 A
Issuance Date 2021-08-31
Abatement Due Date 2021-09-27
Current Penalty 8583.0
Initial Penalty 8583.0
Final Order 2021-10-01
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a):The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: At the jobsite, employees were using portable extension ladders without training, exposing them to a fall hazard over six feet, on or about May 12, 2021 The Domingos 54 Construction Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.1060(a), which was contained in OSHA inspection number 1467585, citation number 1, item number 2 and was affirmed as a final order on 9-21-2020, with respect to a workplace located at 10813 Applewood Range Way, Tampa, FL.
344675855 0420600 2020-03-05 10813 APPLEWOOD RANGE WAY, TAMPA, FL, 33647
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2020-08-26
Emphasis L: FALL
Case Closed 2023-10-17

Related Activity

Type Accident
Activity Nr 1550097
Type Inspection
Activity Nr 1468093
Safety Yes
Type Inspection
Activity Nr 1468101
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2020-08-27
Abatement Due Date 2020-09-16
Current Penalty 10390.0
Initial Penalty 10390.0
Final Order 2020-09-21
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. The employer fails to ensure effective protection against falls as required by the standard, as demonstrated on or about March 5, 2020, at a new home construction site located at 10813 Applewood Range Way, Tampa, FL, when employees installing sheeting on a roof, without having training on fall protection, are exposed to a fall hazard of 10-feet to ground level. To abate this violation, the employer must ensure that all employees are trained on the use of fall protection when an employee works 6 feet or more above lower levels. Pursuant to 29 CFR 1903.19, the employer must submit documents describing the measures it is taking to ensure compliance, including an explanation of how these steps protect its employees from falls associated with ladder misuse.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2020-08-27
Abatement Due Date 2020-09-16
Current Penalty 4453.0
Initial Penalty 4453.0
Final Order 2020-09-21
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: a. The employer fails to ensure effective protection against falls from ladders as required by the standard, as demonstrated on or about March 5, 2020, at a new home construction site located at 10813 Applewood Range Way, Tampa, FL, when employees installing sheeting on a roof by accessing the roof with A-frame and extension ladders, without having training on ladder use and safety, are exposed to a fall hazard of 10-feet to ground level. To abate this violation, the employer must ensure that all employees are trained on the safe use of ladders when an employee uses a ladder for access to a higher level. Pursuant to 29 CFR 1903.19, the employer must submit documents describing the measures it is taking to ensure compliance, including an explanation of how these steps protect its employees from falls associated with ladder misuse.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2020-08-27
Current Penalty 134937.0
Initial Penalty 134937.0
Final Order 2020-09-21
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. The employer fails to ensure effective protection against falls as required by the standard, as demonstrated on or about March 5, 2020, at a new home construction site located at 10813 Applewood Range Way, Tampa, FL, when employees installing sheeting on a roof, without fall protection, are exposed to a fall hazard of 10-feet to ground level. To abate this violation, the employer must ensure that all employees are provided with and utilize fall protection or install a guardrail or safety net system when an employee works 6 feet or more above lower levels. Pursuant to 29 CFR 1903.19, the employer must submit documents describing the measures it is taking to ensure compliance, including an explanation of how these steps protect its employees from fall hazards.
Citation ID 03001
Citaton Type Other
Standard Cited 19040029 B03
Issuance Date 2020-08-27
Abatement Due Date 2020-10-15
Current Penalty 1485.0
Initial Penalty 1485.0
Final Order 2020-09-21
Nr Instances 1
Nr Exposed 30
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.29(b)(3): Each recordable injury or illness was not recorded on the OSHA 300 Log and 301 Incident Report within seven (7) calendar days of receiving information that a recordable injury or illness has occurred: a. At the job site located at 10813 Applewood Range Way, Tampa, FL, the employer did not record a work-related fatality on the OSHA 300 log within 7 days of its occurrence, on or about 12 March 2020.
344162425 0420600 2019-07-15 9756-9760 PEMBROOKE PINES, RUSKIN, FL, 33570
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-07-15
Emphasis L: FALL, P: FALL
Case Closed 2024-01-09

Related Activity

Type Inspection
Activity Nr 1416731
Safety Yes
Type Inspection
Activity Nr 1416718
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2019-09-06
Abatement Due Date 2019-10-02
Current Penalty 5834.0
Initial Penalty 5834.0
Final Order 2019-10-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) On or about July 15, 2019, at the job-site located at 9756-9760 Pembroke Pines, Ruskin, Florida, an employee was wood decking fascia while standing on a 6 inch wide wood plank, exposing to a 5 feet fall hazard.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2019-09-06
Abatement Due Date 2019-10-02
Current Penalty 5834.0
Initial Penalty 5834.0
Final Order 2019-10-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a) On or about July 15, 2019, at the job-site located at 9756-9760 Pembroke Pines, Ruskin, FL, an employee was wood decking fascia while standing on a 6 inch wide wood plank. The wood plank was laying at one side on the top rung of a 6 ft. Fiberglass Single Sided Step Ladder, exposing to a 5 feet fall hazard.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2019-09-06
Abatement Due Date 2019-10-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-10-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about July 15, 2019 at the residential construction job-site located at 9756-9760 Pembroke Pines, Ruskin, Florida. Employees, performing wood roof decking were exposed to a 6 foot fall hazard, in that the top cap of a Fiberglass Single Sided Step Ladder was used to reach the working surface.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260102 A01
Issuance Date 2019-09-06
Abatement Due Date 2019-10-02
Current Penalty 11669.0
Initial Penalty 11669.0
Final Order 2019-10-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On or about July 15, 2019 at the job-site located at 9756-9760 Pembroke Pines, Ruskin, Florida; employees using pneumatic nail gun to install wood decking on the garage fascia and a circular saw to cut plywood were not wearing eye protection, exposing to struck-by hazards. DOMINGOS 54 CONSTRUCTION INC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA inspection number 1388590, citation number 1, item number 1 and was affirmed as a final order on 6/24/2019, with respect to a workplace located at 13319 Saw Palm Creek Trail, Lakewood Ranch, FL.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2019-09-06
Abatement Due Date 2019-10-02
Current Penalty 20420.0
Initial Penalty 20420.0
Final Order 2019-10-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At the job site, employees working at elevations of 6 feet or more above ground are not protected from fall hazards by the use of a personal fall arrest system. The employer fails to assure effective protection against falls as required by the standard, as demonstrated on July 15, 2019, when employees doing roof deck installation work on a 5:12 pitch residential home at 9756-9760 Pembroke Pines, Ruskin, FL 33570 without fall protection were exposed to fall hazards of 17 ft.-4in. from the leading edge of the building. DOMINGOS 54 CONSTRUCTION INC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1388590, citation number 1, item number 3 and was affirmed as a final order on 6/24/2019, with respect to a workplace located at 13319 Saw Palm Creek Trail, Lakewood Ranch, FL.
Citation ID 03001
Citaton Type Other
Standard Cited 19260405 G02 IV
Issuance Date 2019-09-06
Abatement Due Date 2019-10-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-10-21
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) For the power cord of the Makita Circular Saw 5007F (S/N: 2033222), at the jobsite located at 9756-9760 Pembroke Pines, Ruskin, FL, on or about July15, 2019.
Citation ID 03002
Citaton Type Other
Standard Cited 19260416 E01
Issuance Date 2019-09-06
Abatement Due Date 2019-10-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-10-21
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) For the extension cord used to connect the Makita 5Circular Saw 5007F (S/N: 2033222) at the jobsite located at 9756-9760 Pembroke Pines, Ruskin, FL, on or about July15, 2019.
344129960 0420600 2019-07-03 4503 NIGHT STAR TRAIL, ODESSA, FL, 33556
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-07-03
Emphasis L: FALL, P: FALL
Case Closed 2024-01-09

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2019-08-13
Current Penalty 20420.0
Initial Penalty 20420.0
Final Order 2019-09-16
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 4503 Night Star Trail- Employees in the process of decking the 6 in 12 slope (vertical to horizontal) roof, were exposed to a 10'11" fall hazard, in that, fall protection equipment was not installed or utilized, observed on or about 07/03/2019. DOMINGOS 54 CONSTRUCTION INC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1388590, citation number 1, item number 3 and was affirmed as a final order on 6/24/2019, with respect to a workplace located at 13319 Saw Palm Creek Trail, Lakewood Ranch (FL).
343885901 0420600 2019-03-27 13319 SAW PALM CREEK TRAIL, LAKEWOOD RANCH, FL, 34211
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-03-27
Emphasis L: FALL, P: FALL
Case Closed 2020-10-10

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-05-28
Abatement Due Date 2019-06-21
Current Penalty 1363.8
Initial Penalty 2273.0
Final Order 2019-06-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On or about March 27, 2019 at the job-site located at 13319 Saw Palm Creek Trail, Lakewood Ranch (FL); three employees using pneumatic nail guns while installing wood trusses and decking were not wearing eye protection, exposing to struck-by hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B03
Issuance Date 2019-05-28
Abatement Due Date 2019-06-21
Current Penalty 1363.8
Initial Penalty 2273.0
Final Order 2019-06-24
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: On or about March 27, 2019, at the job site located at job-site located at 13319 Saw Palm Creek Trail, Lakewood Ranch (FL): a) at the south and north sides of the residential building, the scaffold used by employees as a catch platform, access to the roof and to carry materials and tools from the ground to the roof were 23 inches from the edge of the building to the platform. b) at the west side of the residential building, the scaffold used by employees as a catch platform, access to the roof and to carry materials and tools from the ground to the roof was 22 inches from the edge of the building to the platform.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-05-28
Abatement Due Date 2019-06-21
Current Penalty 2386.8
Initial Penalty 3978.0
Final Order 2019-06-24
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about March 27, 2019 at the job-site located at 13319 Saw Palm Creek Trail, Lakewood Ranch (FL), four employees were installing roof trusses with pneumatic nail guns, exposed to a 16 foot fall hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2019-05-28
Abatement Due Date 2019-06-21
Current Penalty 1363.8
Initial Penalty 2273.0
Final Order 2019-06-24
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about March 27, 2019 at the job-site located at 13319 Saw Palm Creek Trail, Lakewood Ranch (FL). Employees, performing wood roof decking and truss installation were exposed to a 8 foot fall hazard, in that, the Werner (20 ft.) extension ladder was not extend 3 feet above the landing surface of the wall walker platform.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19261053 B15
Issuance Date 2019-05-28
Abatement Due Date 2019-06-21
Current Penalty 2046.0
Initial Penalty 3410.0
Final Order 2019-06-24
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: a) On or about March 27, 2019 at the job-site located at 13319 Saw Palm Creek Trail, Lakewood Ranch (FL); for Werner extension (20 ft.) ladder used to access and egress the wall walker system installed along the north, west and south sides of the residential building. The ladder had visible signs of damage included broken fly sections and missing anti-slip safety shows.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19261053 B16
Issuance Date 2019-05-28
Abatement Due Date 2019-06-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-06-24
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately: a) On or about March 27, 2019 at the job-site located at 13319 Saw Palm Creek Trail, Lakewood Ranch (FL); for Werner extension (20 ft.) ladder used to access and egress the wall walker system installed along the north, west and south sides of the residential building. The ladder had visible signs of damage included broken fly sections and missing anti-slip safety shows.
Citation ID 02001
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2020-08-19
Abatement Due Date 2020-09-08
Current Penalty 325.0
Initial Penalty 325.0
Final Order 2020-09-24
Nr Instances 6
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. On or about 8/12/2020, the employer failed to submit certification of corrective action and documentation: a) for citation 1, item 1 issued on 5/28/2020 with an abatement due on 6/21/2020, b) for citation 1, item 2 issued on 5/28/2020 with an abatement due on 6/21/2020, c) for citation 1, item 3 issued on 5/28/2020 with an abatement due on 6/21/2020, d) for citation 1, item 4 issued on 5/28/2020 with an abatement due on 6/21/2020, e) for citation 1, item 5-a issued on 5/28/2020 with an abatement due on 6/21/2020, and f) for citation 1, item 5-b issued on 5/28/2020 with an abatement due on 6/21/2020.
343856092 0420600 2019-03-07 4511 LONG BRANCH LANE, PALMETTO, FL, 34221
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-03-18
Emphasis L: FALL, P: FALL
Case Closed 2024-01-11

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-07-08
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-08-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For employees working at 4511 Long Branch Lane in Palmetto, as observed on or about March 7, 2019. Employees were installing framing lumber without the use of a fall protection system, exposing to a fall height of 10 feet.
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-02-28
Emphasis L: FALL, P: FALL
Case Closed 2024-01-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-08-23
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-09-23
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) At the roof - employees were exposed to a fall of 19 feet 4 inches while installing the roof deck, on or about February 28, 2019.
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-02-14
Emphasis L: FALL, P: FALL
Case Closed 2023-10-17

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-07-17
Abatement Due Date 2019-08-12
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-08-14
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: (a) At 309 Paradiso Drive in Apollo Beach where employees doing roofing activity at a two-story residential construction project using circular saws and pneumatic nail guns were exposed to eye injuries from flying particles while installing plywood sheets (sheeting). The employees were not using eye or face protection as observed on or about 02/14/2019.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-07-17
Abatement Due Date 2019-08-12
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-08-14
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) At 309 Paradiso Drive in Apollo Beach, employees were installing plywood sheets (sheeting) at a two-story residential construction project without the use of a fall protection system and exposed to a fall of approximately 21 feet. On or about 02/14/2019.

Date of last update: 01 Apr 2025