Search icon

VENE REMODELATION CORP - Florida Company Profile

Company Details

Entity Name: VENE REMODELATION CORP
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation

VENE REMODELATION CORP is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock.
In Florida, Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 19 Apr 2018 (7 years ago)
Date of dissolution: 27 Sep 2019 (5 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (5 years ago)
Document Number: P18000036766
Address: 14576 POTANOW TRL, ORLANDO, FL 32837
Mail Address: 14576 POTANOW TRL, ORLANDO, FL 32837
ZIP code: 32837
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MONTOYA, J FELIX Agent 6033 W AMELIA ST, ORLANDO, FL 32835
MONTOYA, J FELIX President 6033 W AMELIA ST, ORLANDO, FL 32835

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -

Documents

Name Date
Domestic Profit 2018-04-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344227145 0420600 2019-04-18 9807 VISTA MAGNOLIA LN., ORLANDO, FL, 32836
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2019-04-18
Emphasis L: FALL
Case Closed 2019-11-19

Related Activity

Type Inspection
Activity Nr 1394466
Safety Yes
Type Inspection
Activity Nr 1394481
Safety Yes
Type Inspection
Activity Nr 1397284
Safety Yes
Type Inspection
Activity Nr 1394491
Safety Yes
Type Inspection
Activity Nr 1394405
Safety Yes
Type Inspection
Activity Nr 1419055
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2019-10-15
Abatement Due Date 2019-10-25
Current Penalty 1705.2
Initial Penalty 2842.0
Final Order 2019-10-31
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a. On or about 04/18/2019, 9807 Vista Magnolia Ln. - personal fall protection was not attached to the basket anchor point while conducting framing work from an aerial lift, exposing the employee to an approximate 15 feet fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 A02
Issuance Date 2019-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-10-31
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): a. On or about 04/18/2019, 9807 Vista Magnolia Ln. - an employee was exposed to about 15 feet fall hazard while conducting framing work was not provided with fall protection training.
343347449 0420600 2018-07-31 13601 LIANA ROSE WAY, TAMPA, FL, 33618
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-07-31
Emphasis L: FALL, P: FALL
Case Closed 2018-09-18

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-09-04
Current Penalty 3104.4
Initial Penalty 5174.0
Final Order 2018-09-18
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 13601 Liana Rose Way - Employees in the process of decking the 6 in 12 slope (vertical to horizontal) roof, were exposed to a 10 foot fall hazard, in that, fall protection equipment was not installed or utilized, observed on or about 7/31/2018.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-09-04
Current Penalty 3104.4
Initial Penalty 5174.0
Final Order 2018-09-18
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) 13601 Liana Rose Way - Employees were exposed to a 10 foot fall hazard, in that, the Werner extension ladder did not extend 3 foot above the roof edge, observed on or about 7/31/2018.
Citation ID 02001
Citaton Type Other
Standard Cited 19260100 A
Issuance Date 2018-09-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-09-18
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) 13601 Liana Rose Way - An employee working below the area where employees were in the process of framing activities on the roof, was exposed to being struck by falling objects, observed on or about 7/31/2018.