Search icon

FRED WHITE, INC. - Florida Company Profile

Company Details

Entity Name: FRED WHITE, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

FRED WHITE, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 26 Feb 2018 (7 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P18000019818
FEI/EIN Number 475177186

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 38127 CHURCH ST, UMATILLA, FL, 32784, US
Mail Address: 38127 CHURCH ST, UMATILLA, FL, 32784, US
ZIP code: 32784
County: Lake
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
WHITE FRED President 38127 CHURCH ST, UMATILLA, FL, 32784
WHITE ODESSA Vice President 38127 CHURCH ST, UMATILLA, FL, 32784
WHITE ODESSA Agent 38127 CHURCH ST, UMATILLA, FL, 32784

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -

Documents

Name Date
Domestic Profit 2018-02-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
335956793 0419700 2012-08-15 2060 SW COLLEGE ROAD, OCALA, FL, 34474
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-08-17
Emphasis L: FALL, L: EISAOF
Case Closed 2018-09-19

Related Activity

Type Inspection
Activity Nr 595759
Safety Yes
Type Inspection
Activity Nr 595718
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260251 A01
Issuance Date 2012-09-27
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2012-12-13
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.251(a)(1): Rigging equipment for material handling was not inspected prior to use on each shift and as necessary during its use to ensure that it was safe: a. On or about August 15, 2012, the nylon web slings used to raise steel joists were not inspected prior to use, exposing employees to a struck by hazard. ABATEMENT DOCUMENTATION AND CERTIFICATION IS NOT REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260251 A02 I
Issuance Date 2012-09-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-12-13
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.251(a)(2)(i): The employer did not ensure that rigging equipment had permanently affixed and legible identification markings as prescribed by the manufacturer that indicated the recommended safe working load: a. On or about August 15, 2012, two nylon web slings used to raise steel joists were missing the slings identification markings. ABATEMENT DOCUMENTATION AND CERTIFICATION IS NOT REQUIRED
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260251 E08
Issuance Date 2012-09-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-12-13
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.251(e)(8): Synthetic web slings were not immediately removed from service if any of the following conditions specified in 1926.251(e)(8)(i) through (e)(8)(v) were present: (i) Acid or caustic burns; (ii) Melting or charring of any part of the sling surface; (iii) snags, punctures, tears, or cuts; (iv) broken or worn stitches; or (v) distortion of fittings. a. On or about August 15, 2012, the nylon web slings used to raise steel joists were damaged, exposing employees to a struck by hazard. ABATEMENT DOCUMENTATION AND CERTIFICATION IS NOT REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2012-09-27
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2012-12-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a: On or about August 15, 2012, employees of the mason contractor, G.P. Masonry & Concrete of Ocala, Inc., installed unprotected rebar in the area under steel erection activities by employees of Fred White. The unprotected rebar was protruding from concrete block, exposing employees of Fred White to an impalement hazard. ABATEMENT DOCUMENTATION AND CERTIFICATION IS NOT REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19260753 D01
Issuance Date 2012-09-27
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2012-12-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.753(d)(1): Routes for suspended loads were not pre-planned to ensure that no employee was required to work directly below a suspended load: a. On or about August 15, 2012, employees of Fred White, steel erector, lowered and raised steel joists over employees of G.P. Masonry & Concrete of Ocala, Inc., exposing them to the hazard of being struck by the steel joists. ABATEMENT DOCUMENTATION AND CERTIFICATION IS NOT REQUIRED