Entity Name: | SOUTHERN COMFORT BUILDERS INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
SOUTHERN COMFORT BUILDERS INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 19 Feb 2018 (7 years ago) |
Last Event: | AMENDMENT |
Event Date Filed: | 19 Jul 2018 (7 years ago) |
Document Number: | P18000016880 |
FEI/EIN Number |
36-4891710
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1303 Gulf Beach Hwy, PENSACOLA, FL, 32507, US |
Mail Address: | 1303 Gulf Beach Hwy, PENSACOLA, FL, 32507, US |
ZIP code: | 32507 |
County: | Escambia |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
baudendistel donna | President | 1303 Gulf Beach Hwy, Pensacola, FL, 32507 |
baudendistel donna | Secretary | 1303 Gulf Beach Hwy, Pensacola, FL, 32507 |
baudendistel donna | Treasurer | 1303 Gulf Beach Hwy, Pensacola, FL, 32507 |
baudendistel joe | Owne | 1303 Gulf Beach Hwy, Pensacola, FL, 32507 |
BAUDENDISTEL JOE | Agent | 1303 Gulf Beach Hwy, PENSACOLA, FL, 32507 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G23000062920 | BRADLEY PLUMBING AND HEATING | ACTIVE | 2023-05-19 | 2028-12-31 | - | 1303 GULF BEACH HWY, PENSACOLA, FL, 32507 |
G23000062925 | EAST BAY PLUMBING AND HEATING | ACTIVE | 2023-05-19 | 2028-12-31 | - | 1303 GULF BEACH HWY, PENSACOLA, FL, 32507 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF MAILING ADDRESS | 2022-04-15 | 1303 Gulf Beach Hwy, PENSACOLA, FL 32507 | - |
REGISTERED AGENT ADDRESS CHANGED | 2021-04-15 | 1303 Gulf Beach Hwy, PENSACOLA, FL 32507 | - |
CHANGE OF PRINCIPAL ADDRESS | 2020-04-14 | 1303 Gulf Beach Hwy, PENSACOLA, FL 32507 | - |
AMENDMENT | 2018-07-19 | - | - |
AMENDMENT | 2018-04-11 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-17 |
ANNUAL REPORT | 2023-04-16 |
ANNUAL REPORT | 2022-04-15 |
ANNUAL REPORT | 2021-04-15 |
ANNUAL REPORT | 2020-02-26 |
ANNUAL REPORT | 2019-02-01 |
Amendment | 2018-07-19 |
Amendment | 2018-04-11 |
Domestic Profit | 2018-02-19 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345802037 | 0418600 | 2022-02-23 | 330 EAST SUNSET AVE, PENSACOLA, FL, 32507 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2022-04-13 |
Current Penalty | 2983.0 |
Initial Penalty | 4972.0 |
Final Order | 2022-05-09 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1):Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about February 23, 2022 and times prior; residential construction site at 330 East Sunset Ave, Pensacola, FL: The employer failed to ensure employees conducting work activities from the third level scaffold platform were protected from falls in that the platform level was not fully planked and missing a mid rail. b) On or about February 23, 2022 and times prior; residential construction site at 330 East Sunset Ave, Pensacola, FL: The employer failed to ensure employees using the second level platform to gain access on/off the third level platform were protected from falls. The second level platform (1 foot 8 inches below the third level platform) was not fully planked and had no guardrails installed which exposed employees to fall hazards. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2022-04-13 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2022-05-09 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about February 23, 2022 and times prior; residential construction site at 330 East Sunset Ave, Pensacola, FL: The employer failed to ensure employees conducting work activities from a fabricated tube scaffold had proper access on/off scaffold platforms in that employees climbed the end frames and cross bracing due to no adequate ladder being set-up, exposing them to fall hazards of various heights. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2022-04-13 |
Abatement Due Date | 2022-04-21 |
Current Penalty | 2487.0 |
Initial Penalty | 4144.0 |
Final Order | 2022-05-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. a) On or about February 23, 2022 and times prior; residential construction site at 330 East Sunset Ave, Pensacola, FL: The employer failed to ensure an employee on the first roof level was protected from falls to the ground. b) On or about February 23, 2022 and times prior; residential construction site at 330 East Sunset Ave, Pensacola, FL: The employer failed to an employee working from the porch was protected from falls to the ground. |
Inspection Type | Unprog Rel |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1987-03-17 |
Case Closed | 1987-04-20 |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260404 B01 I |
Issuance Date | 1987-03-27 |
Abatement Due Date | 1987-03-31 |
Nr Instances | 1 |
Nr Exposed | 2 |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2533888608 | 2021-03-15 | 0491 | PPP | 1303 Gulf Beach Hwy, Pensacola, FL, 32507-3001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 01 Apr 2025
Sources: Florida Department of State