Entity Name: EKO CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

EKO CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 09 Oct 2017 (8 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P17000081322
FEI/EIN Number 61-1858874

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1812 N HIAWASSEE RD, ORLANDO, FL, 32818, US
Mail Address: 1812 N HIAWASSEE RD, ORLANDO, FL, 32818, US
ZIP code: 32818
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
RIVERA ORTIZ ERICKSON President 1812 N HIAWASSEE RD, ORLANDO, FL, 32818
VIAJE SERVI USA Agent 1812 N HIAWASSEE RD, ORLANDO, FL, 32818

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
REGISTERED AGENT NAME CHANGED 2018-06-07 VIAJE SERVI USA -

Documents

Name Date
ANNUAL REPORT 2018-06-07
Domestic Profit 2017-10-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343655296 0419700 2018-12-14 92 MARQUESA CIR. LOT 60, SAINT JOHNS, FL, 32259
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-01-17
Emphasis L: FALL, P: FALL
Case Closed 2020-10-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2019-02-22
Current Penalty 1705.0
Initial Penalty 1705.0
Final Order 2019-03-25
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about December 7, 2018: An employee was providing a piece of lumber to a worker on the roof which had tools such as but not limited t a circular saw and a pneumatic nail gun and was not using a hard hat; exposing the employee to head injuries.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A02
Issuance Date 2019-02-22
Current Penalty 1705.0
Initial Penalty 1705.0
Final Order 2019-03-25
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(2): The employer did not ensure that each affected employee used eye protection that provided side protection when there is a hazard from flying objects. a) On or about December 7, 2018: An employee was operating a pneumatic nail gun and a circular saw while performing framing activities and was not using safety glasses to protect him from flying objects; exposing the employee to eye injuries.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-02-22
Current Penalty 3410.0
Initial Penalty 3410.0
Final Order 2019-03-25
Nr Instances 2
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about December 7, 2018: Four employees were observed installing roof sheathing on a roof with a pitch of 5:12 and were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection; exposing the employees to a 10-feet fall hazard. b) On or about December 7, 2018: Two employees were observed installing bracing elements and trim at the porch area with a pitch of 5:12 and were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection; exposing the employees to a 13-feet fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2019-02-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-03-25
Nr Instances 1
Nr Exposed 9
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part. a) On or about December 7, 2018: the employer did not initiate and maintain such programs to ensure worker safety, including a program of frequent and regular inspections, person it designates, to ensure workers use appropriate fall protection, head protection and eye protection and to promptly correct safety and health hazards.
Citation ID 02002
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2019-02-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-03-25
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about December 7, 2017: The employer did not provided fall protection training certification for employees exposed to fall hazards while performing framing activities.