Search icon

ANAYA CONSTRUCTION BUILDING SERVICES INC - Florida Company Profile

Company Details

Entity Name: ANAYA CONSTRUCTION BUILDING SERVICES INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ANAYA CONSTRUCTION BUILDING SERVICES INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 02 Oct 2017 (8 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P17000079271
FEI/EIN Number 82-3226450

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 510 PROCLAMATION DR, TAMPA, FL, 33613, US
Mail Address: 510 PROCLAMATION DR, TAMPA, FL, 33613, US
ZIP code: 33613
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
AVILES LUIS R President 510 PROCLAMATION DR, TAMPA, FL, 33613
AVILES LUIS R Agent 510 PROCLAMATION DR, TAMPA, FL, 33613

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2018-04-27 510 PROCLAMATION DR, TAMPA, FL 33613 -
CHANGE OF MAILING ADDRESS 2018-04-27 510 PROCLAMATION DR, TAMPA, FL 33613 -
REGISTERED AGENT ADDRESS CHANGED 2018-04-27 510 PROCLAMATION DR, TAMPA, FL 33613 -

Documents

Name Date
ANNUAL REPORT 2018-04-27
Domestic Profit 2017-10-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343252268 0419700 2018-06-22 659 LOS ALAMOS LOT 31, SAINT AUGUSTINE, FL, 32095
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-07-17
Emphasis L: FALL, P: FALL
Case Closed 2020-10-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2018-07-24
Current Penalty 1663.0
Initial Penalty 1663.0
Final Order 2018-09-05
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a) On or about June 22, 2018: Two employees were observed operating a pneumatic nail gun when installing roof truss elements without using any type of eye protection. Employees were exposed to injuries.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2018-07-24
Current Penalty 6652.0
Initial Penalty 6652.0
Final Order 2018-09-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about June 22, 2018: Two employees were observed installing roof trusses elements and securing trusses and the employees were not protected by guardrail system, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure. Employees were exposed to a 9-feet 4-inches fall hazard. Anaya Construction Building Services Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1291473, citation number 1, item number 1 and was affirmed as a final order on March 27, 2018, with respect to a workplace located at Starkey Ranch 12782 Munro Ln. Odessa, FL 33556.
Citation ID 03001
Citaton Type Repeat
Standard Cited 19260503 B01
Issuance Date 2018-07-24
Abatement Due Date 2018-08-10
Current Penalty 207.0
Initial Penalty 207.0
Final Order 2018-09-05
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about June 22, 2018: Certification of fall protection training was not provided by the employer for employees exposed to fall hazards. Anaya Construction Building Services Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(b)(1), which was contained in OSHA inspection number 1291473, citation number 2, item number 1 and was affirmed as a final order on March 27, 2018, with respect to a workplace located at Starkey Ranch 12782 Munro Ln. Odessa, FL 33556.
342914736 0420600 2018-01-31 STARKEY RANCH 12782 MUNRO LN., ODESSA, FL, 33556
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-01-31
Emphasis P: FALL, L: FALL
Case Closed 2020-11-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-03-01
Current Penalty 5174.0
Initial Penalty 5174.0
Final Order 2018-03-27
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Starkey Ranch - 12782 Munro Ln. - Employees in the process of decking the 5 in 12 slope (vertical to horizontal) roof, were exposed to a 19'9" fall hazard, in that, fall protection equipment was not installed or utilized, observed on or about 01/31/2018.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2018-03-01
Current Penalty 2956.0
Initial Penalty 2956.0
Final Order 2018-03-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: (a) Starkey Ranch - 12782 Munro Ln. - Employees were exposed to a fall hazard up to 10'9", in that, a hand rail was not installed on the enclosed stairs between the first and second floors, observed on or about 01/31/2018.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C12
Issuance Date 2018-03-01
Current Penalty 2956.0
Initial Penalty 2956.0
Final Order 2018-03-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: (a) Starkey Ranch - 12782 Munro Ln. - Employees were exposed to a fall hazard up to 10'9", in that, a guardrail system was not installed on the second floor stairway landing, observed on or about 01/31/2018.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2018-03-01
Abatement Due Date 2018-04-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-03-27
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. (a) The employer does not have fall protection training certification for employees, observed on or about 01/31/2018.