Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-05-01
|
Emphasis |
L: FALL
|
Case Closed |
2022-07-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2018-10-19 |
Abatement Due Date |
2018-11-07 |
Current Penalty |
4434.0 |
Initial Penalty |
4434.0 |
Final Order |
2018-11-14 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) A) At Boyette Park in Riverview Fl, where employees applying stucco to a residence worked from a scaffold system. The second level was not fully planked and exposed the employees to a fall hazard of 13. 5 feet as observed on or about 05/01/2018. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2018-10-19 |
Abatement Due Date |
2018-11-07 |
Current Penalty |
4434.0 |
Initial Penalty |
4434.0 |
Final Order |
2018-11-14 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) At Boyette Park in Riverview Fl, where employees applying stucco to a residence worked from a scaffold system. No ladders to reach the second level were available and employees were exposed to a fall hazard of 13. 5 feet as observed on or about 05/01/2018. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2018-10-19 |
Abatement Due Date |
2018-11-07 |
Current Penalty |
4434.0 |
Initial Penalty |
4434.0 |
Final Order |
2018-11-14 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: A) At the back of the house in Boyette Park, Riverview Fl, where employees applying stucco to a residence worked from a scaffold system. Guardrails were not used in the scaffold second level exposing employees to a fall hazard of 13. 5 feet, as observed on or about 05/01/2018. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19260451 C01 I |
Issuance Date |
2018-10-19 |
Abatement Due Date |
2018-11-07 |
Current Penalty |
4434.0 |
Initial Penalty |
4434.0 |
Final Order |
2018-11-14 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(1)(i): Guys, ties, and braces were not installed at locations where horizontal members support both inner and outer legs. A) At Boyette Park in Riverview Fl, where employees applying stucco to a residence worked from a scaffold system. The scaffold had cross braces in only one side exposing the employees to a fall hazard of 13. 5 feet as observed on or about 05/01/2018. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2018-10-19 |
Abatement Due Date |
2018-11-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-11-14 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: A) At Boyette Park in Riverview Fl, where employees applying stucco to a residence worked from a scaffold system that had no mudsills, exposing to a fall hazard of 13. 5 feet. As observed on or about 05/01/2018. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-10-19 |
Abatement Due Date |
2018-11-07 |
Current Penalty |
4434.0 |
Initial Penalty |
4434.0 |
Final Order |
2018-11-14 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): A) At Boyette Park in Riverview Fl, two employees applying stucco to a residence worked from high pitch roof without using a fall protection system were exposed to a fall hazard of approximately 10 feet. As observed on or about 05/01/2018. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260451 F03 |
Issuance Date |
2018-10-19 |
Abatement Due Date |
2018-11-07 |
Current Penalty |
415.0 |
Initial Penalty |
415.0 |
Final Order |
2018-11-14 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: A) At Boyette Park in Riverview Fl, where employees applying stucco to a residence worked from a scaffold system that was not inspected before being used and exposed employees to a fall hazard of approximately 10 feet as observed on or about 05/01/2018. |
|
|