Search icon

PLATFORM CONSTRUCTION INC - Florida Company Profile

Company Details

Entity Name: PLATFORM CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

PLATFORM CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 08 Aug 2017 (8 years ago)
Date of dissolution: 24 Feb 2020 (5 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 24 Feb 2020 (5 years ago)
Document Number: P17000066762
FEI/EIN Number APPLIED FOR

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 60 BAYOU DR, LOT 10, FORT WALTON BEACH, FL, 32547
Mail Address: 60 BAYOU DR, LOT 10, FORT WALTON BEACH, FL, 32547
ZIP code: 32547
County: Okaloosa
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
AGUILERA JERAL President 60 BAYOU DR, FORT WALTON BEACH, FL, 32547
AGUILERA JERAL Agent 60 BAYOU DR, FORT WALTON BEACH, FL, 32547

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2020-02-24 - -

Documents

Name Date
VOLUNTARY DISSOLUTION 2020-02-24
ANNUAL REPORT 2019-04-29
ANNUAL REPORT 2018-04-27
Domestic Profit 2017-08-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344074752 0419700 2019-06-11 2078 SCENIC GULF DRIVE LOT 16, MIRAMAR BEACH, FL, 32550
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-06-11
Emphasis L: FALL, P: FALL
Case Closed 2020-11-18

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2019-10-07
Current Penalty 3751.0
Initial Penalty 3751.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about June 11, 2019, on the 3rd floor of an open balcony, an employee working underneath two framers was not wearing a protective helmet, exposing himself to being hit or struck-by falling debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-10-07
Current Penalty 3751.0
Initial Penalty 3751.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about June 11, 2019, while conducting framing operations, an employee using a NR83A2 Hitachi pneumatic nail gun was not wearing safety glasses, exposing himself to being hit or struck-by flying debris.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2019-10-07
Current Penalty 4376.0
Initial Penalty 4376.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about June 11, 2019, on the 3rd floor of an open balcony, an employee performing framing operations was not protected from a 35-foot fall hazard by use of a guardrail system, safety net system or personal fall arrest system.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2019-10-07
Current Penalty 3751.0
Initial Penalty 3751.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about June 11, 2019, on the 3rd level of a structure, two employees used an 8-foot Werner ladders' top step to access the top of a structure, exposing themselves to a fall hazard.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2019-10-07
Current Penalty 7502.0
Initial Penalty 7502.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about June 11, 2019, on top of a structure, two employees performing framing operations were not protected from a 9 feet fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternate fall protection. Platform Construction, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1402914, citation number 01, item number 001 and was affirmed as a final order on June 26, 2019, with respect to a workplace located at 20609 Front Beach Road, Panama City Beach, Florida 32413.
Citation ID 03001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2019-10-07
Abatement Due Date 2019-11-01
Current Penalty 351.0
Initial Penalty 351.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and maintained to provide compliance with the general safety and health provisions of the standard: a. On or about June 11, 2019, at the worksite, a safety and health program had not been initiated and maintained which addressed the following basic elements:
Citation ID 03002
Citaton Type Other
Standard Cited 19260050 D01
Issuance Date 2019-10-07
Abatement Due Date 2019-11-01
Current Penalty 351.0
Initial Penalty 351.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.50(d)(1): First-aid supplies were not easily accessible when required: a. On or about June 11, 2019, at the jobsite located at Lot 16, 2078 Scenic Gulf Drive, Miramar Beach, Florida 32550, the employer did provide first-aid kits or supplies for employees engaged in framing operations.
Citation ID 03003
Citaton Type Other
Standard Cited 19260502 K01
Issuance Date 2019-10-07
Abatement Due Date 2019-11-01
Current Penalty 351.0
Initial Penalty 351.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(k)(1): A fall protection plan was not prepared by a qualified person and developed specifically for the site where the leading edge work, precast work, or residential construction work was being performed: a. On or about June 11, 2019, the employer did not develop and implement a site-specific fall protection plan for employees engaged in framing operations which required employees to work at elevations greater than 6-foot at Lot 16, 2078 Scenic Gulf Drive, Miramar Beach, Florida 32550.
Citation ID 03004
Citaton Type Other
Standard Cited 19260503 A01
Issuance Date 2019-10-07
Abatement Due Date 2019-11-01
Current Penalty 351.0
Initial Penalty 351.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. On or about June 11, 2019, employees performing framing operations were not provided training by the employer to recognize the hazards of falling and did not train each employee in the procedures to be followed in order to minimize these hazards.
Citation ID 03005
Citaton Type Other
Standard Cited 19261060 A01
Issuance Date 2019-10-07
Abatement Due Date 2019-11-01
Current Penalty 351.0
Initial Penalty 351.0
Final Order 2019-12-11
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1): The employer did not provide a training program for each employee using ladders as necessary, enabling each employee to recognize hazards related to ladders and the procedures to be followed to minimize these hazards: a. On or about June 11, 2019, employees using ladders at the jobsite was not trained to recognize, control or minimize hazards at the jobsite.
344029145 0419700 2019-05-21 20609 FRONT BEACH ROAD, PANAMA CITY BEACH, FL, 32413
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-05-21
Emphasis L: FALL, L: FORKLIFT, P: FALL
Case Closed 2020-08-19

Related Activity

Type Inspection
Activity Nr 1402898
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-06-26
Current Penalty 5304.0
Initial Penalty 5304.0
Final Order 2019-08-09
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At a temporary residential construction site, on or about May 21, 2019, four employees were working on the fourth floor of a new construction home, without the use of any fall protection systems in place, while exposed to a 33-foot, 8-inch fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C12
Issuance Date 2019-06-26
Current Penalty 3031.0
Initial Penalty 3031.0
Final Order 2019-08-09
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: a. At a temporary residential construction site, on or about May 21, 2019, four employees used an unguarded staircase landing and were exposed to a 10-foot fall hazard.