Search icon

SARAVIA CONSTRUCTION GROUP INC - Florida Company Profile

Company Details

Entity Name: SARAVIA CONSTRUCTION GROUP INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation

SARAVIA CONSTRUCTION GROUP INC is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock.
In Florida, Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 01 Aug 2017 (8 years ago)
Date of dissolution: 28 Sep 2018 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 28 Sep 2018 (6 years ago)
Document Number: P17000065011
Address: 3025 SW 13TH COURT, FT LAUDERDALE, FL 33312
Mail Address: 3025 SW 13TH COURT, FT LAUDERDALE, FL 33312
ZIP code: 33312
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
SARAVIA, EDGARDO J Agent 3025 SW 13TH COURT, FT LAUDERDALE, FL 33312
SARAVIA, EDGARDO J President 3025 SW 13TH COURT, FT LAUDERDALE, FL 33312

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2018-09-28 - -

Documents

Name Date
Domestic Profit 2017-08-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342941986 0418800 2018-01-12 120 NE 4TH STREET THE WHITNEY (ONE20FOURTH), FORT LAUDERDALE, FL, 33301
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-01-12
Emphasis L: FALL, P: FALL
Case Closed 2023-10-23

Related Activity

Type Inspection
Activity Nr 1294206
Safety Yes
Type Inspection
Activity Nr 1294343
Safety Yes
Type Inspection
Activity Nr 1289865
Safety Yes
Type Inspection
Activity Nr 1290015
Safety Yes
Type Inspection
Activity Nr 1290024
Safety Yes
Type Inspection
Activity Nr 1294380
Safety Yes
Type Inspection
Activity Nr 1321780
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2018-06-28
Abatement Due Date 2018-07-25
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-09-13
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: On or about December 29, 2017, at 120 NE 4th Street, The Whitney, (one20fourth), FORT LAUDERDALE, FL, 33301, employees were operating, assembling, dissembling and moving two-point suspended scaffolds without training by a Competent Person, so as to enable the employees to recognize any hazards associated with the work in question therefore exposing the employees to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 02001
Citaton Type Other
Standard Cited 19260502 D20
Issuance Date 2018-06-28
Abatement Due Date 2018-07-25
Current Penalty 311.0
Initial Penalty 311.0
Final Order 2018-09-13
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(20): The employer did not provide for prompt rescue of employees in the event of a fall or did not assure that employees were able to rescue themselves: On or about December 29, 2017, at 120 NE 4th Street, The Whitney, (one20fourth), FORT LAUDERDALE, FL, 33301, employees were operating a suspension scaffold, for the purpose of applying stucco, paint and water proofing to a new 14-story high-rise apartment building, while wearing a PFAS, during which the employer did not provide for prompt rescue of employees in the event of a suspended-fall, nor did the employer assure that employees were able to rescue themselves in the event of a suspended-fall; therefore exposing the employees to fall hazards. NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 03001
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2018-10-01
Abatement Due Date 2018-10-19
Current Penalty 311.0
Initial Penalty 311.0
Final Order 2019-02-21
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: The employer did not provide to the Agency, certification and documentation demonstrating that abatement was complete for OSHA Inspection number 1294198, citation 1, item 1, and citation 2, item 1, which were due on 07/25/2018.