Entity Name: | LOCUST CONSTRUCTION SERVICES, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
LOCUST CONSTRUCTION SERVICES, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 18 Jul 2017 (8 years ago) |
Date of dissolution: | 21 Mar 2018 (7 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 21 Mar 2018 (7 years ago) |
Document Number: | P17000060984 |
Address: | 100 SOUTH MILITARY TRAIL, SUITE 13 UNIT 4571, DEERFIELD BEACH, FL, 33442, US |
Mail Address: | 100 SOUTH MILITARY TRAIL, SUITE 13 UNIT 4571, DEERFIELD BEACH, FL, 33442, US |
ZIP code: | 33442 |
County: | Broward |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
DE OLIVEIRA MARCOS | President | 100 SOUTH MILITARY TRAIL SUITE13 UNIT 4571, DEERFIELD BEACH, FL, 33442 |
DE OLIVEIRA MARCOS | Agent | 100 SOUTH MILITARY TRAIL, DEERFIELD BEACH, FL, 33442 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G17000077335 | LOCUST CARPENTRY | EXPIRED | 2017-07-18 | 2022-12-31 | - | 100 SOUTH MILITARY TRAIL, SUITE 13 UNIT 4571, DEERFIELD BEACH, FL, 33442 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2018-03-21 | - | - |
AMENDMENT | 2017-09-05 | - | - |
REGISTERED AGENT NAME CHANGED | 2017-09-05 | DE OLIVEIRA, MARCOS | - |
Name | Date |
---|---|
Amendment | 2017-09-05 |
Domestic Profit | 2017-07-18 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343138434 | 0418800 | 2018-04-16 | 1069 SAVANA OAKS WAY, JENSEN BEACH, FL, 34957 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1322194 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260020 B02 |
Issuance Date | 2018-05-08 |
Abatement Due Date | 2018-05-25 |
Current Penalty | 3624.0 |
Initial Penalty | 5174.0 |
Final Order | 2018-05-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person (i.e., a person who is capable of identifying exist: On or about November 20, 2017, at the above addressed worksite, the employer did not perform on site inspections to identify hazards of a workplace prior to allowing employees to conduct work activities. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261053 B06 |
Issuance Date | 2018-05-08 |
Abatement Due Date | 2018-05-25 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-05-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: On or about November 20, 2017, at the above addressed worksite, an employee who used an extension ladder which was placed against the corner of a new home in construction, was exposed to a fall hazard of approximately 8-feet. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19040039 A02 |
Issuance Date | 2018-05-08 |
Abatement Due Date | 2018-05-25 |
Current Penalty | 3240.0 |
Initial Penalty | 6467.0 |
Final Order | 2018-05-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1904.39(a)(2): The employer failed to report the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, within (24) twenty-four hours: On or about November 20, 2017, at the above addressed worksite, the employer did not report to OSHA an accident which resulted in a hospitalization of an employee. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2017-11-07 |
Case Closed | 2022-03-31 |
Related Activity
Type | Referral |
Activity Nr | 1282415 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2018-01-12 |
Current Penalty | 4530.0 |
Initial Penalty | 6467.0 |
Final Order | 2018-05-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about November 7th, 2017, at the above addressed job site, an employee was exposed to a 12-feet fall hazard while in the process of installing concrete block from a second floor. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2018-01-12 |
Current Penalty | 3882.0 |
Initial Penalty | 6467.0 |
Final Order | 2018-05-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about November 7th, 2017, at the above addressed job site, an employee was exposed to a 12 feet fall hazard when using an extension ladder which did not extend at least 3 feet above the upper landing surface while gaining access to a second floor. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2017-08-15 |
Emphasis | L: FALL |
Case Closed | 2018-03-12 |
Related Activity
Type | Referral |
Activity Nr | 1255859 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1257524 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-12-07 |
Current Penalty | 3169.0 |
Initial Penalty | 6338.0 |
Final Order | 2018-03-08 |
Nr Instances | 2 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about 8/15/17, at the above addressed work site, an employee was exposed to a fall hazard while installing round cap roofing nails on the sheathing of a two-story residential 5:12 pitch roof. b) On or about 8/15/17, at the above addressed work site, an employee was exposed to a fall hazard while standing on trusses and edge of the roof nailing plywood on a two-story residential home. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State