Search icon

JUNIOR'S CARPENTRY SERVICES INC - Florida Company Profile

Company Details

Entity Name: JUNIOR'S CARPENTRY SERVICES INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

JUNIOR'S CARPENTRY SERVICES INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 07 Jul 2017 (8 years ago)
Date of dissolution: 22 Mar 2023 (2 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 22 Mar 2023 (2 years ago)
Document Number: P17000058216
FEI/EIN Number 32-0537185

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2606 ROLYAT STREET, FORT PIERCE, FL, 34947
Mail Address: 2606 ROLYAT STREET, FORT PIERCE, FL, 34947
ZIP code: 34947
County: St. Lucie
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ARROYO EPIFANIO President 2606 ROLYAT STREET, FORT PIERCE, FL, 34947
ARROYO EPIFANIO Agent 2606 ROLYAT STREET, FORT PIERCE, FL, 34947

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2023-03-22 - -

Documents

Name Date
VOLUNTARY DISSOLUTION 2023-03-22
ANNUAL REPORT 2022-01-25
ANNUAL REPORT 2021-02-03
ANNUAL REPORT 2020-01-21
ANNUAL REPORT 2019-03-20
ANNUAL REPORT 2018-04-12
Domestic Profit 2017-07-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345677983 0418800 2021-12-07 4402 PORT SAINT LUCIE BLVD, PORT SAINT LUCIE, FL, 34953
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-12-07
Emphasis L: FALL, P: FALL
Case Closed 2023-04-13

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2021-12-13
Abatement Due Date 2022-01-10
Current Penalty 5617.2
Initial Penalty 9362.0
Final Order 2022-01-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about December 7, 2021, at a new residential construction located at 4402 Port Saint Lucie Blvd, Port Saint Lucie, FL, 34953, employees were exposed to approximately 8-feet fall hazard while installing trusses without using any means of conventional fall protection system. The Junior's Carpentry Services Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1330411, citation number 1, item number 1 and was affirmed as a final order on 09/17/2018, with respect to a workplace located at 7491 SW Cove Ave, Stuart, FL, 34997.
345646111 0418800 2021-11-16 738 MCCRACKEN RD, PORT SAINT LUCIE, FL, 34953
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-11-16
Emphasis L: FALL, P: FALL
Case Closed 2023-04-13

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2021-11-29
Abatement Due Date 2021-12-23
Current Penalty 5617.2
Initial Penalty 9362.0
Final Order 2021-12-21
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about November 16, 2021, at a new residential construction located at 738 McCracken Rd, Port Saint Lucie, FL, 34953, employees were exposed to approximately 8-feet fall hazard while installing trusses without using any means of conventional fall protection system. The Junior's Carpentry Services Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1330411, citation number 1, item number 1 and was affirmed as a final order on 09/17/2018, with respect to a workplace located at 7491 SW Cove Ave, Stuart, FL, 34997.
343304119 0418800 2018-07-17 7491 SW COVE AVENUE, STUART, FL, 34997
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-07-17
Emphasis L: FALL, P: FALL
Case Closed 2018-09-27

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-08-15
Current Penalty 1330.2
Initial Penalty 2217.0
Final Order 2018-09-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about July 17, 2018, on the roof of a residential structure under construction located at 7491 SW Cove Avenue in Stuart, Florida, employees were exposed to a fall hazard of approximately 10 feet - 2 inches when performing carpentry work on the roof of a residential structure while not being protected from falling to the lower level.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2018-08-15
Abatement Due Date 2018-09-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-09-17
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about July 17, 2018, on the roof of a residential structure under construction located at 7491 SW Cove Avenue in Stuart, Florida, employees were exposed to a fall hazard when performing carpentry work prior to be provided with a training program that would enable them to recognize the hazards associated with falls.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-08-15
Current Penalty 1330.2
Initial Penalty 2217.0
Final Order 2018-09-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about July 17, 2018, at the north and west roof edges of a residential structure under construction located at 7491 SW Cove Avenue in Stuart, Florida, employees were exposed to of approximately 10 feet - 2 inches when using ladders that were not extended at least 3 feet past the upper landing surface and were not secured to prevent accidental displacement.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2018-08-15
Abatement Due Date 2018-09-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-09-17
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: On or about July 17, 2018, at the roof edges of a residential structure under construction located at 7491 SW Cove Avenue in Stuart, Florida, employees were exposed to a fall hazard when using extension ladders to gain access to and from a roof prior to be provided with a training program that would enable them to recognize the hazards associated with ladders.