Search icon

GEO' S CONSTRUCTION SVCS OF PSL CORP - Florida Company Profile

Company Details

Entity Name: GEO' S CONSTRUCTION SVCS OF PSL CORP
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

GEO' S CONSTRUCTION SVCS OF PSL CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 09 May 2017 (8 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P17000042016
FEI/EIN Number 61-1845886

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3231 MURA DR, FORT PIERCE, FL, 34982, US
Mail Address: 3231 MURA DR, FORT PIERCE, FL, 34982, US
ZIP code: 34982
County: St. Lucie
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CHAVEZ MARWIN President 3231 MURA DR, FORT PIERCE, FL, 34982
CHAVEZ MARWIN Agent 3231 MURA DR, FORT PIERCE, FL, 34982

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2018-03-22 3231 MURA DR, APT 3231, FORT PIERCE, FL 34982 -
CHANGE OF MAILING ADDRESS 2018-03-22 3231 MURA DR, APT 3231, FORT PIERCE, FL 34982 -
REGISTERED AGENT ADDRESS CHANGED 2018-03-22 3231 MURA DR, APT 3231, FORT PIERCE, FL 34982 -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J20000397147 ACTIVE 1000000869192 ST LUCIE 2020-11-30 2030-12-09 $ 764.74 STATE OF FLORIDA, DEPARTMENT OF REVENUE, FORT PIERCE SERVICE CENTER, 337 N US HIGHWAY 1 STE 207-B, FORT PIERCE FL349504255

Documents

Name Date
ANNUAL REPORT 2018-03-22
Domestic Profit 2017-05-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342923703 0418800 2018-02-02 402 SE HIBISCUS AVE, STUART, FL, 34997
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-02-02
Emphasis L: FALL
Case Closed 2020-09-28

Related Activity

Type Referral
Activity Nr 1305663
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2018-02-05
Abatement Due Date 2018-02-23
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-03-05
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 2 February, 2018, at the above addressed jobsite, two employees were performing stucco work while on the second level of a two tier tubular welded frame scaffold that was not fully planked at the level they were working at, exposing the employees to a fall hazard of approximately 18 feet.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2018-02-05
Abatement Due Date 2018-02-23
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-03-05
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about 2 February, 2018, at the above addressed jobsite, two employees were performing stucco work while on the second level of a two tier tubular welded frame scaffold that did did not had guardrails in one side of the house, exposing two employees to a fall hazard of approximately 18 feet.

Date of last update: 02 Apr 2025