Search icon

FCR CONCRETE INC - Florida Company Profile

Company Details

Entity Name: FCR CONCRETE INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation

FCR CONCRETE INC is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock.
In Florida, Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 31 Mar 2017 (8 years ago)
Document Number: P17000030085
FEI/EIN Number 82-1024065

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1834 NW 22ND CT, APT 4, MIAMI, FL 33125
Mail Address: 1834 NW 22ND CT, APT 4, MIAMI, FL 33125
ZIP code: 33125
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
REED, FREDY C Agent 1834 NW 22ND CT, APT 4, MIAMI, FL 33125
Taylor, Deyanira President 1834 NW 22ND CT, Apt 4 MIAMI, FL 33125
Campbell, Fredy Vice President 1834 NW 22nd Ct, Apt 4 Miami, FL 33125

Documents

Name Date
ANNUAL REPORT 2025-01-13
ANNUAL REPORT 2024-01-08
ANNUAL REPORT 2023-01-30
ANNUAL REPORT 2022-01-08
ANNUAL REPORT 2021-01-06
ANNUAL REPORT 2020-01-21
ANNUAL REPORT 2019-01-28
ANNUAL REPORT 2018-01-23
Domestic Profit 2017-03-31

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343308219 0418800 2018-07-17 7855 NW 104TH AVE APEX PHASE II, BUILDING 11, DORAL, FL, 33178
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-07-17
Emphasis L: FALL, P: FALL
Case Closed 2020-02-24

Related Activity

Type Inspection
Activity Nr 1332031
Safety Yes
Type Inspection
Activity Nr 1336032
Safety Yes
Type Inspection
Activity Nr 1336036
Safety Yes
Type Inspection
Activity Nr 1336021
Safety Yes
Type Inspection
Activity Nr 1336039
Safety Yes
Type Inspection
Activity Nr 1330841
Safety Yes
Type Inspection
Activity Nr 1331783
Safety Yes
Type Inspection
Activity Nr 1331790
Safety Yes
Type Inspection
Activity Nr 1329738
Safety Yes
Type Inspection
Activity Nr 1329744
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2018-12-18
Abatement Due Date 2019-01-15
Current Penalty 1663.2
Initial Penalty 2772.0
Final Order 2019-01-10
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. On or about July 17, 2018, at jobsite located on 7855 NW 104th Ave, Apex Phase II, Building 11, Doral FL 33178, employees performing overhand bricklaying were exposed to chemical burns while using Portland Cement without appropriate hand protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2018-12-18
Abatement Due Date 2019-01-15
Current Penalty 2328.0
Initial Penalty 3880.0
Final Order 2019-01-10
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On or about July 17, 2018, at jobsite located on 7855 NW 104th Ave, Apex Phase II, Building 11, Doral FL 33178, employees performing overhand bricklaying were exposed to fall hazards while working from a 10 foot 3 inch scaffold that was lacking planks to fully deck the working surface.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2018-12-18
Abatement Due Date 2019-01-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-10
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: On or about July 17, 2018, at jobsite located on 7855 NW 104th Ave, Apex Phase II, Building 11, Doral FL 33178, employees performing overhand bricklaying were exposed to a 14 foot 8 inch fall hazard while working from a scaffold in which the frame was supported by a partially erected brick wall; and two of the poles/leg posts were left unsupported.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 G01 VI
Issuance Date 2018-12-18
Abatement Due Date 2019-01-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-10
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity). On or about July 17, 2018, at jobsite located on 7855 NW 104th Ave, Apex Phase II, Building 11, Doral FL 33178, employees performing overhand bricklaying were exposed to fall hazards while working from a 10 foot 3 inch high scaffold without means of fall protection on its ends and open sides.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2018-12-18
Abatement Due Date 2019-01-15
Current Penalty 2328.0
Initial Penalty 3880.0
Final Order 2019-01-10
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or persons: On or about July 17, 2018, at jobsite located on 7855 NW 104th Ave, Apex Phase II, Building 11, Doral FL 33178, an employee while carrying a wooden plank was exposed to approximately 10 feet fall hazards while walking along the edge of a concrete wall without any means of fall protection.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2018-12-18
Abatement Due Date 2019-01-15
Current Penalty 1663.2
Initial Penalty 2772.0
Final Order 2019-01-10
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) On or about July 17, 2018, at jobsite located on 7855 NW 104th Ave, Apex Phase II, Building 11, Doral FL 33178, the employer did not develop or implement a written hazard communication program to address hazards related to chemicals such as but not limited to Portland Cement, for employees performing overhand bricklaying.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19101200 G10
Issuance Date 2018-12-18
Abatement Due Date 2019-01-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-10
Nr Instances 1
Nr Exposed 7
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(10): The employer did not ensure that, in all cases, the required information was provided for each hazardous chemical, and was readily accessible during each work shift to employees when they were in their work area(s): (Construction Reference: 1926.59) On or about July 17, 2018, at jobsite located on 7855 NW 104th Ave, Apex Phase II, Building 11, Doral FL 33178, employer did not maintain accessible SDS for all chemicals in the work area for employees performing overhand bricklaying.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19101200 G10
Issuance Date 2018-12-18
Abatement Due Date 2019-01-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-10
Nr Instances 1
Nr Exposed 7
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(10): The employer did not ensure that, in all cases, the required information was provided for each hazardous chemical, and was readily accessible during each work shift to employees when they were in their work area(s): (Construction Reference: 1926.59) On or about July 17, 2018, at jobsite located on 7855 NW 104th Ave, Apex Phase II, Building 11, Doral FL 33178, employer did not provide effective training on hazards associate to chemicals, such as but not limited to Portland Cement, for employees performing overhand bricklaying.

Date of last update: 18 Feb 2025

Sources: Florida Department of State