Search icon

HINOJOZA CONSTRUCTION SERVICES INC - Florida Company Profile

Company Details

Entity Name: HINOJOZA CONSTRUCTION SERVICES INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

HINOJOZA CONSTRUCTION SERVICES INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 16 Mar 2017 (8 years ago)
Last Event: AMENDMENT
Event Date Filed: 20 Jun 2017 (8 years ago)
Document Number: P17000024787
FEI/EIN Number 820885873

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7018 Fleming Ave, Gibsonton, FL, 33534, US
Mail Address: 7018 FLEMING ST, GIBSONTON, FL, 33534, US
ZIP code: 33534
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
HINOJOZA BENHUMEA LUIS ALBERTO President 7018 FLEMING ST, GIBSONTON, FL, 33534
HINOJOZA JOCELYN JULIET Vice President 7018 FLEMING ST, GIBSONTON, FL, 33534
HINOJOZA BENHUMEA LUIS ALBERTO Agent 7018 FLEMING ST, GIBSONTON, FL, 33534

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2021-09-30 HINOJOZA BENHUMEA, LUIS ALBERTO -
CHANGE OF PRINCIPAL ADDRESS 2021-03-30 7018 Fleming Ave, Gibsonton, FL 33534 -
AMENDMENT 2017-06-20 - -
REGISTERED AGENT ADDRESS CHANGED 2017-06-20 7018 FLEMING ST, GIBSONTON, FL 33534 -

Documents

Name Date
ANNUAL REPORT 2024-04-10
ANNUAL REPORT 2023-02-02
ANNUAL REPORT 2022-03-28
AMENDED ANNUAL REPORT 2021-09-30
ANNUAL REPORT 2021-03-30
ANNUAL REPORT 2020-05-15
ANNUAL REPORT 2019-02-27
ANNUAL REPORT 2018-03-29
Amendment 2017-06-20
Domestic Profit 2017-03-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343310769 0420600 2018-07-18 US HWY 41 & 19TH AVE NW, RUSKIN, FL, 33570
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-07-18
Emphasis L: FALL, P: FALL
Case Closed 2019-11-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2018-10-25
Current Penalty 1140.0
Initial Penalty 2217.0
Final Order 2018-12-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about July 18, 2018, at the jobsite, an employee installing lath mesh from the second level of a frame walkthrough scaffold exposed to a 14 feet fall hazard in that the scaffold was not fully planked.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C01
Issuance Date 2018-10-25
Current Penalty 1140.0
Initial Penalty 2217.0
Final Order 2018-12-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a) On or about 07/18/2018, at the jobsite, employees were exposed to a fall hazard while standing/working from the metal frame scaffold with a height to base width ratio of 4.67 to 1. The scaffolding was not restrained from tipping.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2018-10-25
Current Penalty 1140.0
Initial Penalty 2217.0
Final Order 2018-12-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) On or about July, 18, 2018, at the jobsite, employees working from a metal frame walkthrough scaffold exposed to a fall hazard in that the scaffold was missing mud sills at the footing.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2018-10-25
Current Penalty 1140.0
Initial Penalty 2217.0
Final Order 2018-12-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, stairway-type ladders, ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used for access: a) On or about July, 18, 2018, at the jobsite, employees were climbing the frame of the scaffolding for access/egress, exposing to a fall hazard.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2018-10-25
Current Penalty 1140.0
Initial Penalty 2217.0
Final Order 2018-12-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about July 18, 2018, at the jobsite, an employee working from a frame walkthrough scaffold was exposed to a 14 feet fall hazard in that the scaffold was missing a guardrail at the working level.
343341889 0420600 2018-07-16 SUN TRUST BANK HWY 41 S & 19TH ST, RUSKIN, FL, 33570
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-07-16
Emphasis L: FALL, P: FALL
Case Closed 2019-12-26

Related Activity

Type Inspection
Activity Nr 1330936
Safety Yes
Type Inspection
Activity Nr 1330953
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2019-01-15
Abatement Due Date 2019-02-04
Current Penalty 1660.0
Initial Penalty 2772.0
Final Order 2019-01-30
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: (a) On July 16, 2018, an employee installing wire mesh on the exterior wall of a commercial building using a Genie 40 High Reach aerial lift was not wearing body harness with a lanyard attached to the basket, exposing to a 15 feet fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 G02 III
Issuance Date 2019-01-15
Abatement Due Date 2019-02-04
Current Penalty 1940.0
Initial Penalty 3326.0
Final Order 2019-01-30
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: (a) On 07/16/2018, an extension cord used to power a DeWalt DWD110 3/8 VSR Drill was damaged in in that it was spliced and not properly repaired, exposing employees to electrical hazards.