Search icon

FATHER & SON STEEL WORKS INC. - Florida Company Profile

Company Details

Entity Name: FATHER & SON STEEL WORKS INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

FATHER & SON STEEL WORKS INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 15 Mar 2017 (8 years ago)
Document Number: P17000024467
FEI/EIN Number 82-0882904

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2301 nw 151 st, opa locka, FL, 33054, US
Mail Address: 2301 nw 151 st, opa locka, FL, 33054, US
ZIP code: 33054
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
rosales alain President 2301 nw 151 st, Opa Locka, FL, 33054
rosales alain Vice President 2301 nw 151 st, Opa Locka, FL, 33054
ROSALES ALAIN Agent 2301 nw 151 st, opa locka, FL, 33054

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2018-04-27 2301 nw 151 st, opa locka, FL 33054 -
CHANGE OF MAILING ADDRESS 2018-04-27 2301 nw 151 st, opa locka, FL 33054 -
REGISTERED AGENT ADDRESS CHANGED 2018-04-27 2301 nw 151 st, opa locka, FL 33054 -

Documents

Name Date
ANNUAL REPORT 2024-04-03
ANNUAL REPORT 2023-03-31
ANNUAL REPORT 2022-03-28
ANNUAL REPORT 2021-04-26
ANNUAL REPORT 2020-03-26
ANNUAL REPORT 2019-04-24
ANNUAL REPORT 2018-04-27
Domestic Profit 2017-03-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346772619 0418800 2023-06-15 8070 NW 36TH STREET RAISING CANE'S, DORAL, FL, 33166
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-06-15
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2023-09-28
Abatement Due Date 2023-10-18
Current Penalty 3572.0
Initial Penalty 3572.0
Final Order 2023-11-22
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 6/15/2023, at 8070 NW 36th Street, Doral, Florida, an employee was exposed to a 9.5 feet fall hazard when working on an concrete wall without using any means of fall protection.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2023-09-28
Abatement Due Date 2023-10-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-11-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who was exposed to fall hazards that enabled each employee to recognize the hazards of falling and train each employee in the procedures to be followed in order to minimize these hazards: On or about 6/15/2023, t 8070 NW 36th Street, Doral, Florida, an employee was exposed to a 9.5 feet fall hazard when working on an concrete wall without being trained to recognize and avoid the hazards associated with falls.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2023-09-28
Abatement Due Date 2023-10-18
Current Penalty 3572.0
Initial Penalty 3572.0
Final Order 2023-11-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On or about 06/15/2023, at 8070 NW 36th Street, Doral, Florida, an employee was exposed to a fall hazard greater than six feet when using a step (A-frame) ladder in the closed position to access the top of a concrete wall that was 9.5 feet high.

Date of last update: 02 Apr 2025

Sources: Florida Department of State